Experience with the use of the circular stapler in rectal surgery
- 1 July 1992
- journal article
- review article
- Published by Wolters Kluwer Health in Diseases of the Colon & Rectum
- Vol. 35 (7), 696-706
- https://doi.org/10.1007/bf02053764
Abstract
This report provides our personal experience along with a general overview of the use of the circular stapler in rectal surgery. To determine the results of our experience with the use of the circular stapler for construction of anastomoses following resection, a series of 215 anastomoses performed in 214 patients was reviewed. The patients ranged in age from 33 to 88 years. There were 116 men and 98 women. Indications for operation included malignancy, diverticular disease, villous adenoma, Crohn's disease, and rectal procidentia. The types of operation performed included removal of varying portions of the large bowel. The anastomosis was performed in a uniform manner with the EEA (United States Surgical Corp., Norwalk, CT) and more recently the CEEA (United States Surgical Corp., Norwalk, CT). The operative mortality was 0.47 percent, with the death being unrelated to the anastomosis. Intraoperative complications encountered included bleeding, difficult extraction, instrument failure, incomplete doughnuts, deficient anastomoses, and miscellaneous problems. Early postoperative complications included one leak and a number of complications unrelated to the anastomoses. Anastomotic stenosis developed in 27 patients, but only 8 were permanent and only 3 of these were symptomatic. Two of these patients were treated with balloon dilatation. Anastomotic recurrences developed in 13.1 percent of patients. Our experience gained with the circular stapling device and that reported in the literature have shown it to be a reliable method of performing anastomoses to the rectum in a safe and expeditious manner.Keywords
This publication has 40 references indexed in Scilit:
- Simple techniques of enlarging the diameter of the bowel lumen for the performance of end-to-end anastomoses using the EEA staplerDiseases of the Colon & Rectum, 1984
- Experience with Stapling in Rectal SurgerySurgical Clinics of North America, 1984
- The EEA stapler in low colorectal anastomosesDiseases of the Colon & Rectum, 1982
- EEA stapler in low anterior anastomosisDiseases of the Colon & Rectum, 1982
- INITIAL CLINICAL EXPERIENCE WITH THE EEA STAPLERAnz Journal of Surgery, 1982
- Anastomosis with EEA stapler after anterior colonic resectionDiseases of the Colon & Rectum, 1981
- Complications of anterior resection of the rectum using the EEA stapling deviceBritish Journal of Surgery, 1981
- The low stapled anastomosisBritish Journal of Surgery, 1981
- Stapled anastomosis in colorectal surgeryDiseases of the Colon & Rectum, 1981
- Anterior resection for mid-rectal cancer with the EEA stapling instrumentThe American Journal of Surgery, 1980