Respiratory system, lung, and chest wall impedances in anesthetized dogs
- 1 July 1984
- journal article
- research article
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 57 (1), 34-39
- https://doi.org/10.1152/jappl.1984.57.1.34
Abstract
Impedances of the respiratory system (Zrs) and lung (ZL) were measured in anesthetized and paralyzed dogs at frequencies between 4 and 64 Hz. Zrs was measured at functional residual capacity (FRC) and with mean transpulmonary pressures (Ptp) of 12 and 30 cmH2O; ZL was measured with the chest wall open at FRC and Ptp = 12 cmH2O. From these data chest wall impedances were derived at FRC and 12 cmH2O. Effective resistances of the respiratory system, lung and chest wall were all frequency dependent. At frequencies below 22 Hz frequency dependence of respiratory system resistance was due to the frequency dependence of the chest wall, whereas at higher frequencies it was due to frequency dependence of the lung. Analysis of the impedance data between 4 and 32 Hz provided estimates of resistance, inertance and compliance of the lung, chest wall and respiratory system. At FRC, 41% of the respiratory system resistance was due to the lung and 59% was associated with the chest wall. Nearly all of the respiratory inertance (98%) was due to the lung. Lung compliance was approximately twice that of the chest wall, the former accounting for .apprx. 1/3 of respiratory elasticity. As lung volume was increased, respiratory resistance and compliance decreased; inertance also decreased, although this change was not significant.This publication has 10 references indexed in Scilit:
- Interaction of oscillatory and unidirectional flows in straight tubes and an airway castJournal of Applied Physiology, 1982
- Pulmonary impedance in dogs measured by forced random noise with a retrograde catheterJournal of Applied Physiology, 1982
- Frequency dependence and partitioning of respiratory impedance in dogsJournal of Applied Physiology, 1981
- Forced oscillatory respiratory parameters following papain exposure in dogsJournal of Applied Physiology, 1979
- Estimating central and peripheral respiratory resistanceJournal of Applied Physiology, 1978
- Relationship of central and peripheral airway resistance to lung volume in dogsJournal of Applied Physiology, 1978
- Respiratory parameter estimation using forced oscillatory impedance dataJournal of Applied Physiology, 1977
- Effect of gas physical properties and flow on lower pulmonary resistanceJournal of Applied Physiology, 1976
- Measurement of Inertia of the Lungs at Increased Ambient PressureJournal of Applied Physiology, 1956
- Oscillation Mechanics of Lungs and Chest in ManJournal of Applied Physiology, 1956