A revised plot is presented of the comparison with theory of precision ML orbital-electron capture ratios. The experimental points for Cd109 and Sn113 have been relocated in accordance with the revised calculations of Vatai for L x-ray and K x-ray excape, respectively. From the revised plot, it is clear that there is a systematic disagreement of the experimental ML capture ratios with exchange-corrected theory.