The influence of temperature on the amplitude and frequency components of the EMG during brief and sustained isometric contractions
- 1 August 1980
- journal article
- research article
- Published by Springer Nature in European Journal of Applied Physiology
- Vol. 44 (2), 189-200
- https://doi.org/10.1007/bf00421098
Abstract
The influence of temperature on the amplitude and frequency components of the EMG power spectra of the surface EMG recorded over the forearm muscles was examined in five male and five female subjects during brief and fatiguing isometric contractions of their handgrip muscles. Brief (3 s) isometric contractions were exerted at tensions ranging between 10 and 100% of each subject's maximum strength while fatiguing contractions were exerted at tensions of 25, 40, and 70% of their maximum strength. The temperature of the muscles during those contractions was varied by placing the forearms of the subjects in a controlled temperature water bath at temperatures of 10, 20, 30, and 40‡ C. The results of these experiments showed that the center frequency of the power spectra of the surface EMG was directly related to the temperature of the exercising muscles during brief isometric contractions. During fatiguing isometric contractions, the amplitude of the EMG increased while the center frequency of the EMG power spectra decreased for all tensions examined.This publication has 31 references indexed in Scilit:
- MUSCLE ACTION POTENTIALS STUDIED BY FREQUENCY ANALYSIS AND DURATION MEASUREMENTActa Neurologica Scandinavica, 2009
- Amplitude of the surface electromyogram during fatiguing isometric contractionsMuscle & Nerve, 1979
- Signal characteristics of EMG during fatigueEuropean Journal of Applied Physiology, 1977
- Isometric strength and endurance during the menstrual cycleEuropean Journal of Applied Physiology, 1976
- Vocational Electromyography: Studies of Localized Muscle Fatigue at the Assembly LineErgonomics, 1975
- Simulation of electromyograms showing interference patternsElectroencephalography and Clinical Neurophysiology, 1970
- Influence of Temperature on Isometric Contractions of Rat Skeletal MusclesNature, 1968
- Some Problems in the Quantitative Evaluation of Muscle Fatigue by Frequency Analysis of the ElectromyogramJournal of the Anthropological Society of Nippon, 1965
- The blood flow through active and inactive muscles of the forearm during sustained hand‐grip contractionsThe Journal of Physiology, 1963
- Hyperaemia following arterial occlusion or exercise in the warm and cold human forearmThe Journal of Physiology, 1959