Lymphangion coordination minimally affects mean flow in lymphatic vessels
- 1 August 2007
- journal article
- Published by American Physiological Society in American Journal of Physiology-Heart and Circulatory Physiology
- Vol. 293 (2), H1183-H1189
- https://doi.org/10.1152/ajpheart.01340.2006
Abstract
The lymphatic system returns interstitial fluid to the central venous circulation, in part, by the cyclical contraction of a series of “lymphangion pumps” in a lymphatic vessel. The dynamics of individual lymphangions have been well characterized in vitro; their frequencies and strengths of contraction are sensitive to both preload and afterload. However, lymphangion interaction within a lymphatic vessel has been poorly characterized because it is difficult to experimentally alter properties of individual lymphangions and because the afterload of one lymphangion is coupled to the preload of another. To determine the effects of lymphangion interaction on lymph flow, we adapted an existing mathematical model of a lymphangion (characterizing lymphangion contractility, lymph viscosity, and inertia) to create a new lymphatic vessel model consisting of several lymphangions in series. The lymphatic vessel model was validated with focused experiments on bovine mesenteric lymphatic vessels in vitro. The model was then used to predict changes in lymph flow with different time delays between onset of contraction of adjacent lymphangions (coordinated case) and with different relative lymphangion contraction frequencies (noncoordinated case). Coordination of contraction had little impact on mean flow. Furthermore, orthograde and retrograde propagations of contractile waves had similar effects on flow. Model results explain why neither retrograde propagation of contractile waves nor the lack of electrical continuity between lymphangions adversely impacts flow. Because lymphangion coordination minimally affects mean flow in lymphatic vessels, lymphangions have flexibility to independently adapt to local conditions.Keywords
This publication has 27 references indexed in Scilit:
- Regional Variations of Contractile Activity in Isolated Rat LymphaticsMicrocirculation, 2004
- Inhibition of the active lymph pump by flow in rat mesenteric lymphatics and thoracic ductThe Journal of Physiology, 2002
- Co‐ordination of contractile activity in guinea‐pig mesenteric lymphatics.The Journal of Physiology, 1997
- Lymphatic pump function curves in awake sheepAmerican Journal of Physiology-Regulatory, Integrative and Comparative Physiology, 1996
- Importance of Valves and Lymphangion Contractions in Determining Pressure Gradients in Isolated Lymphatics Exposed to Elevations in Outflow PressureMicrovascular Research, 1995
- Effect of outflow pressure on lymphatic pumping in vitroAmerican Journal of Physiology-Regulatory, Integrative and Comparative Physiology, 1993
- Characterization of intact mesenteric lymphatic pump and its responsiveness to acute edemagenic stressAmerican Journal of Physiology-Heart and Circulatory Physiology, 1989
- Equivalent circuit technique for lymph flow studiesAmerican Journal of Physiology-Heart and Circulatory Physiology, 1986
- Effect of outflow pressure on lung lymph flow in unanesthetized sheepJournal of Applied Physiology, 1985
- Contractile stimuli in collecting lymph vesselsAmerican Journal of Physiology-Heart and Circulatory Physiology, 1977