In vivo histological response to anodized and anodized/hydrothermally treated titanium implants
- 1 July 2003
- journal article
- research article
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 66B (2), 520-525
- https://doi.org/10.1002/jbm.b.10042
Abstract
In the study, characterization of the anodized titanium surface was performed. In addition, histological evaluation and interfacial strength at the bone–implant interface of the characterized surfaces were then evaluated with the use of a rabbit model at 6 and 12 weeks after implantation. Surface treatments consisted of either anodization or anodization followed by hydrothermal treatments. Nontreated titanium surfaces were used as controls in this study. Using scanning‐electron microscopy, porous oxide layers were observed on surfaces of anodized titanium implants, whereas porous oxide layers and HA needles were observed on anodized titanium implants following hydrothermal treatments. X‐ray diffraction analysis showed the oxide layers were consisted mainly of anatase and a little of rutile. By the hydrothermal treatment on the anodizing surface, HA peaks, as well as the peaks of anatase and trace amounts of rutile peaks were observed. In EPMA analysis, the Ca/P ratio for the anodic oxide was 1.54 for anodized surfaces, whereas the Ca/P ratios for HA needles and the anodic oxide were 1.64 and 0.57, respectively, for anodized surfaces following hydrothermal treatments. Although no significant difference was observed for the percent bone contact on all implants evaluated in the in vivo study, the removal torque strength was significantly higher for anodized implants (48.02 ± 5.92 N/cm) than the untreated implants (controls) (27.83 ± 1.78 N/cm) at 6 weeks after implantation. As such, it was concluded that the surface anodized implants resulted in a high interfacial strength at an early implantation period as compared to the nontreated titanium implants. © 2003 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 66B: 520–525, 2003Keywords
This publication has 20 references indexed in Scilit:
- Bone response to radio frequency sputtered calcium phosphate implants and titanium implants in vivoJournal of Biomedical Materials Research, 2001
- Biochemical and morphological studeis on osseointegration in immunological arthritis in rabbitsScandinavian Journal of Plastic and Reconstructive Surgery and Hand Surgery, 1997
- A pilot study comparing screw‐shaped implants. Surface analysis and histologic evaluation of bone healing.Clinical Oral Implants Research, 1996
- Electrochemical impedance spectroscopy study of the passive oxide film on titanium for implant applicationElectrochimica Acta, 1996
- Formation and characterization of anodic titanium oxide films containing Ca and PJournal of Biomedical Materials Research, 1995
- Surface energy characterization of unalloyed titanium implantsJournal of Biomedical Materials Research, 1994
- Retrieval Analysis of a Hydroxyapatite-Coated Hip ProsthesisPublished by Wolters Kluwer Health ,1991
- Calcium phosphate‐coated porous titanium implants for enhanced skeletal fixationJournal of Biomedical Materials Research, 1988
- An evaluation of variables influencing implant fixation by direct bone appositionJournal of Biomedical Materials Research, 1985
- Biocompatibility of titanium implants: Surface science aspectsThe Journal of Prosthetic Dentistry, 1983