Metal ion concentrations in retrieved polyethylene total hip inserts and implications for artifactually high readings in tissue
- 1 November 1993
- journal article
- research article
- Published by Wiley in Journal of Biomedical Materials Research
- Vol. 27 (11), 1349-1355
- https://doi.org/10.1002/jbm.820271102
Abstract
Although there are many studies which document high metal ion concentrations in clinically retrieved tissues surrounding total joint replacements, most investigations have remained cautious in their interpretation due to the artifactual influences of metal particulate. The possible contribution of polyethylene wear debris to artifactually high periprosthetic metal ion concentration readings has not been previously considered. This study documents the potential role of polyethylene particulate contamination in causing artifactually high metal concentration readings in tissues. The data showed metal ion contamination in the polyethylene was progressive at each stage of exposure to metal: from bar stock preparation, to manufacturing, to in vivo ambulation. The manufacturing and machining processes showed a statistically significant (P ≤ .05) increase in metal ion concentrations in the nonarticulated acetabular inserts over bar stock. The results of this study demonstrate that periprosthetic tissue and synovial fluid metal ion concentration data must be interpreted with caution due to possible artifactual problems associated with metal ion contaminated polyethylene particulate. © 1993 John Wiley & Sons, Inc.Keywords
This publication has 17 references indexed in Scilit:
- Cobalt-Alloy Metal Debris in Periarticular Tissues From Total Hip Revision ArthroplastiesPublished by Wolters Kluwer Health ,1992
- Metal Levels in Cemented Total Hip ArthroplastyClinical Orthopaedics and Related Research, 1992
- Implications of Metallic Corrosion in Total Knee ArthroplastyClinical Orthopaedics and Related Research, 1991
- In vivo wear of titanium-alloy hip prostheses.Journal of Bone and Joint Surgery, 1990
- Cobalt, chromium, and nickel concentrations in body fluids of patients with porous‐coated knee or hip prosthesesJournal of Orthopaedic Research, 1989
- Synovial sarcoma associated with total hip replacement. A case report.Journal of Bone and Joint Surgery, 1988
- Pathologic Studies of Total Joint ReplacementOrthopedic Clinics of North America, 1988
- Chromium concentrations in serum, blood clot and urine from patients following total hip arthroplastyBiomaterials, 1985
- The Pathology of Failed Total Joint ArthroplastyPublished by Wolters Kluwer Health ,1982
- The Ionization of Metal Implants in Living TissuesJournal of Bone and Joint Surgery, 1960