Effects of Filtering on Right Ventricular Electrograms Recorded from Endocardial Catheters in Humans
- 1 January 1990
- journal article
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 13 (1), 69-77
- https://doi.org/10.1111/j.1540-8159.1990.tb02005.x
Abstract
Criteria for identifying electrically abnormal myocardium based on analysis of electrogram, amplitude, duration, and morphology have recently been proposed as an aid to catheter mapping in humans. Electrogram characteristics are likely to be influenced by analog filtering and the distance between recording electrodes. These parameters can be varied and differ among electrophysiology laboratories. To determine the magnitude of the effect of low pass and high pass filtering and interelectrode distance on human bipolar right ventricular electrograms eight patients were studied. The signal from a single bipolar electrode pair was recorded simultaneously on five channels with variable filtering. As the high pass filter frequency increased above 10 Hz, the electrogram duration and amplitude decreased. The decrease in amplitude was described by a monoexponential function with a 30% decrease in amplitude at a filter setting of 30 Hz and a 69% decrease at a filter setting of 100 Hz. As the low pass filter frequency decreased from 2,500 to 250 Hz, electrogram characteristics were not significantly altered. Low pas filtering at 100 Hz decreased electrogram amplitude slightly. Neither high nor low pass filter settings or interelectrode distance affected electrogram timing. However, filtering could markedly alter electrogram morphology, introducing the possibility for errors in visual assessment of electrograms. Electrogram duration increased linearly with increasing distance between recording electrodes. The effects of filtering on electrograms were similar regardless of interelectrode spacing. Thus, varying the high pass filter setting over a range that is used clinically (from 1 to 100 Hz) can substantially alter electrogram duration, amplitude, and morphology. Low pass filtering at 250 Hz and above had no effect on these electrograms although it is possible that alterations would be observed in signals from areas of slow conduction that we did not study.(ABSTRACT TRUNCATED AT 250 WORDS)Keywords
This publication has 15 references indexed in Scilit:
- Endocardial catheter mapping in patients in sinus rhythm: relationship to underlying heart disease and ventricular arrhythmias.Circulation, 1986
- Ventricular activation in normal sinus rhythm: Abnormalities with recurrent sustained tachycardia and a history of myocardial infarctionThe American Journal of Cardiology, 1985
- Catheter mapping during sinus rhythm: Relation of local electrogram duration to ventricular tachycardia cycle lengthThe American Journal of Cardiology, 1985
- Fractionated electrical activity and continuous electrical activity: fact or artifact?Circulation, 1984
- Endocardial mapping in humans in sinus rhythm with normal left ventricles: activation patterns and characteristics of electrograms.Circulation, 1984
- Intraoperative electrophysiologic mapping of the ventricles during sinus rhythm in patients with a previous myocardial infarction. Identification of the electrophysiologic substrate of ventricular arrhythmias.Circulation, 1982
- Determinants of ventricular tachycardia in patients with ventricular aneurysms: results of intraoperative epicardial and endocardial mapping.Circulation, 1982
- Techniques of intraoperative electrophysiologic mappingThe American Journal of Cardiology, 1982
- Significance of fragmented ventricular electrograms observed using intracardiac recording techniques in man.Circulation, 1980
- A comparison of unipolar and bipolar electrograms for cardiac pacemaker sensing.Circulation, 1977