False-Positive Results and Contamination in Nucleic Acid Amplification Assays: Suggestions for a Prevent and Destroy Strategy
Top Cited Papers
Open Access
- 1 April 2004
- journal article
- research article
- Published by Springer Nature in European Journal of Clinical Microbiology & Infectious Diseases
- Vol. 23 (4), 289-299
- https://doi.org/10.1007/s10096-004-1100-1
Abstract
Contamination of samples with DNA is still a major problem in microbiology laboratories, despite the wide acceptance of PCR and other amplification techniques for the detection of frequently low amounts of target DNA. This review focuses on the implications of contamination in the diagnosis and research of infectious diseases, possible sources of contaminants, strategies for prevention and destruction, and quality control. Contamination of samples in diagnostic PCR can have far-reaching consequences for patients, as illustrated by several examples in this review. Furthermore, it appears that the (sometimes very unexpected) sources of contaminants are diverse (including water, reagents, disposables, sample carry over, and amplicon), and contaminants can also be introduced by unrelated activities in neighboring laboratories. Therefore, lack of communication between researchers using the same laboratory space can be considered a risk factor. Only a very limited number of multicenter quality control studies have been published so far, but these showed false-positive rates of 9–57%. The overall conclusion is that although nucleic acid amplification assays are basically useful both in research and in the clinic, their accuracy depends on awareness of risk factors and the proper use of procedures for the prevention of nucleic acid contamination. The discussion of prevention and destruction strategies included in this review may serve as a guide to help improve laboratory practices and reduce the number of false-positive amplification results.Keywords
This publication has 72 references indexed in Scilit:
- False‐Positive Results of PCR Testing for Lyme DiseaseClinical Infectious Diseases, 2001
- False-positive polymerase chain reaction results for human papillomavirus in lichen planus: Potential laboratory pitfalls of this procedureJournal of the American Academy of Dermatology, 1996
- Evidence of contamination in PCR laboratory disposablesThe Science of Nature, 1995
- Characterization of contaminating DNA in Taq polymerase which occurs during amplification with a primer set for Legionella 5S ribosomal RNAMolecular and Cellular Probes, 1994
- Use of modified nucleotides and uracil-DNA glycosylase (UNG) for the control of contamination in the PCR-based amplification of RNAMolecular and Cellular Probes, 1992
- Failure of ultra-violet irradiation and autoclaving to eliminate PCR contaminationMolecular and Cellular Probes, 1992
- Taq polymerase contains bacterial DNA of unknown originMolecular and Cellular Probes, 1990
- More light on PCR contaminationNature, 1990
- A past mutation at Isoleucine397 is now a common cause of moderate/mild haemophilia BBritish Journal of Haematology, 1990
- More false-positive problemsNature, 1990