Activation Time Determination by High‐Resolution Unipolar and Bipolar Extracellular Electrograms in the Canine Heart
- 1 March 1995
- journal article
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 6 (3), 174-188
- https://doi.org/10.1111/j.1540-8167.1995.tb00769.x
Abstract
Activation Time Determination by High-Resolution Electrograms. Introduction: To identify the optimal criteria for activation time (AT) determination of bipolar electrograms from normal hearts, a high-resolution cross electrode array comprising 128 unipolar electrodes of 500-μm spacing was used to record extracellular potentials from the left ventricular epicardium of 12 dog hearts. Methods and Results: Recordings were made during broad wavefront propagation (B wave) local elliptical wavefront propagation (E wave). Characteristics of 863 bipolar electrograms (1-mm spacing) were constructed from unipolar data standardized for differences in polarity, then classified morphologically. Features for bipolar AT determination were compared to the time of the negative peak of the firrst temporal derivative of a unipolar electrogram situated mid-way between the bipoles. During B wave, three distinct morphologies were observed: unipbasic (61%), biphasic (23%), and triphasic (16%). Peak voltage of uniphasic and triphasic signals was the best predictor of AT (error: 0.6 ± 0.6 msec and 0.6 ± 0.8 msec, respectively). During E wave, parallel orientation of the bipoles with respect to the direction of impulse propagation wavefront resulted in uniphasic signals (> 99%), while for perpendicular orientation of the bipoles, electrogram morphology was variable. For parallel orientation of the bipoles, peak negative voltage was the best predictor of AT for both longitudinal and transverse propagation, while for perpendicular bipole orientation, peak negative voltage was a less reliable predictor for propagation along both fiber axes. Increasing interpolar distance resulted in a degradation in AT accuracy for B wave (from 0.6 ± 0.6 msec at 1 mm to 1.1 ± 1.2 msec at 7 mm) and for E wave (from 0.4 ± 0.3 msec at 1 mm to 3.1 ± 2.9 msec at 7 mm). Conclusions: (1) The accuracy of bipolar electrograms is sensitive to wavefront direction, bipole orientation, and interpolar distance; (2) peak negative voltage of uniphasic and triphasic signals is a reliable predictor of AT, but only for B wave; (3) a maximum interpolar distance of 2 mm and bipole orientation parallel to the direction of the impulse wavefront are minimally required for accurate determination of AT during impulse propagation initiated near the recording electrodes; and (4) for impulses initiated near the recording site in normal tissue, a bipbasic or triphasic morphology almost certainly indicates that the bipolar electrode is oriented perpendicular to the wavefront direction, irrespective of fiber orientation.Keywords
This publication has 21 references indexed in Scilit:
- Identification of reentry circuit sites during catheter mapping and radiofrequency ablation of ventricular tachycardia late after myocardial infarction.Circulation, 1993
- Criteria for local myocardial electrical activation: effects of electrogram characteristicsIEEE Transactions on Biomedical Engineering, 1993
- Determination of local myocardial electrical activation for activation sequence mapping. A statistical approach.Circulation Research, 1991
- Ventricular arrhythmias in the subacute myocardial infarction period. High-resolution activation and refractory patterns of reentrant rhythms.Circulation Research, 1990
- The Assumptions of Isochronal Cardiac MappingPacing and Clinical Electrophysiology, 1989
- Relating extracellular potentials and their derivatives to anisotropic propagation at a microscopic level in human cardiac muscle. Evidence for electrical uncoupling of side-to-side fiber connections with increasing age.Circulation Research, 1986
- Late, fractionated potentialsThe American Journal of Cardiology, 1985
- Extracellular Potentials Related to Intracellular Action Potentials in the Dog Purkinje SystemCirculation Research, 1972
- Relationship of Surface Electrogram Recordings to Activity in the Underlying Specialized Conducting TissueCirculation, 1972
- Propagation Velocities and Voltage Magnitudes in Local Segments of Dog MyocardiumCirculation Research, 1970