Diagnostic Accuracy of CT-Guided Automated Needle Biopsy of Lung Nodules

Abstract
OBJECTIVE. The purpose of this study was to determine the factors influencing diagnostic accuracy in CT-guided automated needle biopsies of lung nodules.SUBJECTS AND METHODS. One hundred thirty-eight consecutive CT-guided automated needle biopsy procedures were performed in 123 patients (124 pulmonary nodules). Factors for diagnostic accuracy were evaluated through analysis of the procedures, which were classified into a success group (true-positive and true-negative) and a failure group (false-positive and false-negative).RESULTS. Final diagnoses were 81 malignant lesions (91 biopsies) and 43 benign lesions (47 biopsies). More than two CT-guided biopsies were performed for 13 lesions. Seventy lesions were true-positive, 44 were true-negative, three were false-positive, and 21 were false-negative. The overall diagnostic accuracy was 82.6%. The sensitivity for malignancy and specificity for benign lesions were 76.9% and 93.6%, respectively. Positive and negative predictive values were 95.9% and 67.7%, resp...