Initial Experience Using a Forward Directed, High‐Intensity Focused Ultrasound Balloon Catheter for Pulmonary Vein Antrum Isolation in Patients with Atrial Fibrillation
- 10 January 2007
- journal article
- clinical trial
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 18 (2), 136-144
- https://doi.org/10.1111/j.1540-8167.2006.00715.x
Abstract
A high-intensity-focused ultrasound balloon catheter (HIFU-BC) is designed to isolate pulmonary veins (PV) outside the ostia (PV antrum). This catheter uses a parabolic CO2 balloon (behind water balloon) to focus a 20-, 25-, or 30-mm diameter ring of ultrasound forward of the balloon (parallel to catheter shaft). The purpose of this study is to test the safety and efficacy of the HIFU-BC for PV antrum isolation in patients with atrial fibrillation (AF). Twenty-seven patients with paroxysmal (19 patients) or persistent (8 patients) AF were studied. Double transseptal puncture was performed for left atrial deployment of a Lasso catheter (for PV mapping) and the 14 Fr HIFU-BC. The HIFU-BC was positioned outside the PV orifice over a guidewire. HIFU energy (acoustic power 45 watts) was applied for 40 seconds with a 20-mm sonicating ring and 40 or 60 seconds with a 25-mm or 30-mm sonicating ring. No other ablation system was utilized. PV antrum isolation was attempted using HIFU-BC in 78 of 104 PVs (25/27 RSPVs, all 23 LSPVs, all 23 LIPVs, all four left common trunks and 3/27 RIPVs). HIFU-BC successfully isolated 68 (87%) of the 78PV antra with 1-26 (median 3) HIFU applications. The complications include transient bleeding from a distal branch of the left superior PV resulting from guidewire manipulation in one patient and right phrenic nerve injury in another patient. No PV stenosis (>50% narrowing) and no LA-esophageal fistula occurred. At the 12-month follow-up, 16 (59%) of the 27 patients were free of symptomatic episodes of AF (only 3 of the 16 patients were receiving antiarrhythmic medications). Forward-focused HIFU applications isolated PVs outside the PV ostium with elimination of AF in 16 (59%) of the 27 patients at 12 months following the single ablation procedure.Keywords
This publication has 17 references indexed in Scilit:
- Comparison of Electrode Cooling Between Internal and Open Irrigation in Radiofrequency Ablation Lesion Depth and Incidence of Thrombus and Steam PopCirculation, 2006
- Efficacy and Safety of Circumferential Pulmonary Vein Isolation Using a Novel Cryothermal Balloon Ablation SystemJournal of the American College of Cardiology, 2005
- Freedom From Atrial Tachyarrhythmias After Catheter Ablation of Atrial FibrillationCirculation, 2005
- Noninducibility of Atrial Fibrillation as an End Point of Left Atrial Circumferential Ablation for Paroxysmal Atrial FibrillationCirculation, 2004
- Prevalence of Asymptomatic Recurrences of Atrial Fibrillation After Successful Radiofrequency Catheter AblationJournal of Cardiovascular Electrophysiology, 2004
- Time courses and quantitative analysis of atrial fibrillation episode number and duration after circular plus linear left atrial lesions: Trigger elimination or substrate modification: Early or delayed cure?Journal of the American College of Cardiology, 2004
- Atrio-Esophageal Fistula as a Complication of Percutaneous Transcatheter Ablation of Atrial FibrillationCirculation, 2004
- Catheter Ablation for Paroxysmal Atrial FibrillationCirculation, 2003
- Pulmonary Vein Ostium GeometryCirculation, 2003
- Gender Differences in Ventricular Repolarization:Pacing and Clinical Electrophysiology, 2003