Neonatal Screening for Detection of Deafness
- 1 May 1976
- journal article
- research article
- Published by American Medical Association (AMA) in JAMA Otolaryngology–Head & Neck Surgery
- Vol. 102 (5), 297-299
- https://doi.org/10.1001/archotol.1976.00780100083011
Abstract
• To assess various methods of early detection of deafness, a longitudinal study of infants born in the Jerusalem area was performed. The 17,731 newborns were tested by an acoustic signal generator hearing test (Apriton), and the "at risk" for deafness register was applied to them. Twenty-five children were identified as deaf, 14 with severe or profound hearing loss and 11 with moderate or moderately severe loss. The screening hearing test did not prove to be sensitive enough for detection of deafness in newborns, and, therefore, is not considered valid for screening purposes. The at risk for deafness register, which in our program covered 20% of the entire newborn population, proved to be too expensive and impractical; a restricted register, including approximately 7% of the newborns, is suggested. (Arch Otolaryngol102:297-299, 1976)Keywords
This publication has 6 references indexed in Scilit:
- Methods for early detection of hearing loss in infantsThe Journal of Laryngology & Otology, 1971
- Report on the Hearing Screening of 17.000 NeonatesInternational Audiology, 1969
- A Guide to Newborn and Infant Hearing Screening ProgramsJAMA Otolaryngology–Head & Neck Surgery, 1967
- Detection of Hearing Loss in NeonatesJAMA Otolaryngology–Head & Neck Surgery, 1967
- Acoustic Investigation of Newborn InfantsActa Oto-Laryngologica, 1960
- Hard-of-Hearing ChildrenJournal of Educational Sociology, 1933