Clinical importance of increased sensitivity of BacT/Alert FAN aerobic and anaerobic blood culture bottles
- 1 September 1996
- journal article
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 34 (9), 2180-4
- https://doi.org/10.1128/jcm.34.9.2180-2184.1996
Abstract
Two recent multicenter blood culture studies found that BacT/Alert FAN (FAN) bottles (Organon Teknika, Durham, N.C.) had increased yields in detecting bacteremia and fungemia compared with standard BacT/Alert (STD) bottles. Because the clinical importance of this increase in microbial recovery is unknown, we performed a retrospective analysis to determine the frequency with which FAN bottles were the sole means of detecting an episode of bacteremia. There were 1,047 positive blood cultures in which both study bottles were adequately filled and the organism isolated was judged to be the cause of sepsis: 240 (23%) were positive only in FAN bottles and 73 (7%) were positive only in STD bottles. Of a total of 664 episodes of bacteremia, 126 (19%) were identified only by FAN bottles and 43 (7%) were identified only by STD bottles (P < 0.0001). Episodes detected only by FAN bottles more often were recurrent events (23 of 126, or 18%) than episodes detected only by STD bottles (2 of 43, or 5%) (P < 0.05) and more commonly occurred in patients receiving theoretically effective antibiotic therapy (33 of 126 [26%] versus 4 of 43 [9%]) (P < 0.05). The medical records for patients with 127 of these episodes (92 FAN bottles only; 35 STD bottles only) were available for review. More than half of both FAN bottle-only (60 of 92, or 65%) and STD bottle-only (20 of 35, or 57%) episodes were judged to be clinically important. We conclude that FAN bottles improve the detection of bacteremia and that the majority of the additional episodes detected are clinically important. The benefits of the greater yield in specific patient populations must be balanced against the higher costs of FAN bottles.Keywords
This publication has 26 references indexed in Scilit:
- Nosocomial bloodstream infection in critically ill patients. Excess length of stay, extra costs, and attributable mortalityPublished by American Medical Association (AMA) ,1994
- Controlled comparison of the BacT/Alert and BACTEC 660/730 nonradiometric blood culture systems.1992
- Contaminant blood cultures and resource utilization. The true consequences of false-positive results.1991
- Positive bactec resin cultures do not influence antimicrobial selectionDiagnostic Microbiology and Infectious Disease, 1990
- Reliability of Blood Cultures Collected from Intravascular Catheter Versus VenipunctureAmerican Journal of Clinical Pathology, 1987
- Effectiveness of antibiotic removal by the antibiotic-binding blood culture systemsDiagnostic Microbiology and Infectious Disease, 1985
- Improved Recovery of Microorganisms from Patients Receiving Antibiotics with the Antimicrobial Removal DeviceAmerican Journal of Clinical Pathology, 1983
- The Clinical Significance of Positive Blood Cultures: A Comprehensive Analysis of 500 Episodes of Bacteremia and Fungemia in Adults. I. Laboratory and Epidemiologic ObservationsClinical Infectious Diseases, 1983
- Evaluation of the Antimicrobial Removal Device When Used with the BACTEC Blood Culture SystemAmerican Journal of Clinical Pathology, 1982
- The Antimicrobial Removal Device: A Microbiological and Clinical EvaluationAmerican Journal of Clinical Pathology, 1982