Low-Level Detection of Viral Pathogens by a Surface-Enhanced Raman Scattering Based Immunoassay
Top Cited Papers
- 27 August 2005
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 77 (19), 6147-6154
- https://doi.org/10.1021/ac0504159
Abstract
The need for rapid, highly sensitive, and versatile diagnostic tests for viral pathogens spans from human and veterinary medicine to bioterrorism prevention. As an approach to meet these demands, a diagnostic test employing monoclonal antibodies (mAbs) for the selective extraction of viral pathogens from a sample in a chip-scale, sandwich immunoassay format has been developed using surface-enhanced Raman scattering (SERS) as a readout method. The strengths of SERS-based detection include its inherent high sensitivity and facility for multiplexing. The capability of this approach is demonstrated by the capture of feline calicivirus (FCV) from cell culture media that is exposed to a gold substrate modified with a covalently immobilized layer of anti-FCV mAbs. The surface-bound FCVs are subsequently coupled with an extrinsic Raman label (ERL) for identification and quantification. The ERLs consist of 60-nm gold nanoparticles coated first with a layer of Raman reporter molecules and then a layer of mAbs. The Raman reporter molecule is strategically designed to chemisorb as a thiolate adlayer on the gold nanoparticle, to provide a strong and unique spectral signature, and to covalently link a layer of mAbs to the gold nanoparticle. The last feature provides a means to selectively tag substrate-bound FCV. This paper describes the development of the assay, which uses cell culture media as a sample matrix and has a linear dynamic range of 1 × 106−2.5 × 108 viruses/mL and a limit of detection of 1 × 106 viruses/mL. These results reflect the findings from a detailed series of investigations on the effects of several experimental parameters (e.g., salt concentration, ERL binding buffer, and sample agitation), all of which were aimed at minimizing nonspecific binding and maximizing FCV binding efficiency. The performance of the assay is correlated with the number of captured FCV, determined by atomic force microscopy, as a means of method validation.Keywords
This publication has 24 references indexed in Scilit:
- SERRS as a more sensitive technique for the detection of labelled oligonucleotides compared to fluorescenceThe Analyst, 2004
- A rapid detection method for Vaccinia virus, the surrogate for smallpox virusBiosensors and Bioelectronics, 2004
- Virus particle detection by solid phase immunocapture and atomic force microscopyBiochemical and Biophysical Research Communications, 2003
- Femtomolar Detection of Prostate-Specific Antigen: An Immunoassay Based on Surface-Enhanced Raman Scattering and Immunogold LabelsAnalytical Chemistry, 2003
- Surface-enhanced Raman scattering and biophysicsJournal of Physics: Condensed Matter, 2002
- Monoclonal Antibody−Gold Biosensor Chips for Detection of Depurinating Carcinogen−DNA Adducts by Fluorescence Line-Narrowing SpectroscopyAnalytical Chemistry, 2000
- Contact-Inking Stamps for Microcontact Printing of Alkanethiols on GoldLangmuir, 1998
- The effect of temperature on the binding kinetics and equilibrium constants of monoclonal antibodies to cell surface antigensMolecular Immunology, 1990
- The effect of three variables on adsorption of rabbit IgG to colloidal gold.Journal of Histochemistry & Cytochemistry, 1988
- Adsorption of horseradish peroxidase, ovomucoid and anti-immunoglobulin to colloidal gold for the indirect detection of concanavalin A, wheat germ agglutinin and goat anti-human immunoglobulin G on cell surfaces at the electron microscopic level: a new method, theory and application.Journal of Histochemistry & Cytochemistry, 1977