Abstract
Present a new scanning-probe-based data-storage concept called the "millipede" that combines ultrahigh density, terabit capacity, small form factor, and high data rate. Ultrahigh storage density has been demonstrated by a new thermomechanical local-probe technique to store, read back, and erase data in very thin polymer films. With this new technique, nanometer-sized bit indentations and pitch sizes have been made by a single cantilever/tip into thin polymer layers, resulting in a data storage densities of up to 1 Tb/in/sup 2/. High data rates are achieved by parallel operation of large two-dimensional (2-D) atomic force microscope (AFM) arrays that have been batch-fabricated by silicon surface-micromachining techniques. The very large-scale integration (VLSI) of micro/nanomechanical devices (cantilevers/tips) on a single chip leads to the largest and densest 2-D array of 32/spl times/32 (1024) AFM cantilevers with integrated write/read/erase storage functionality ever built. Time-multiplexed electronics control the functional storage cycles for parallel operation of the millipede array chip. Initial areal densities of 100-200 Gb/in/sup 2/ have been achieved with the 32/spl times/32 array chip.Keywords
This publication has 21 references indexed in Scilit:
- Design of atomic force microscope cantilevers for combined thermomechanical writing and thermal reading in array operationJournal of Microelectromechanical Systems, 2002
- Highly parallel data storage system based on scanning probe arraysApplied Physics Letters, 2000
- The “Millipede”—More than thousand tips for future AFM storageIBM Journal of Research and Development, 2000
- VLSI-NEMS chip for parallel AFM data storageSensors and Actuators A: Physical, 2000
- Ultrahigh-density atomic force microscopy data storage with erase capabilityApplied Physics Letters, 1999
- 5×5 2D AFM cantilever arrays a first step towards a Terabit storage deviceSensors and Actuators A: Physical, 1999
- VLSI-NEMS chip for AFM data storagePublished by Institute of Electrical and Electronics Engineers (IEEE) ,1999
- Atomic force microscope-based data storage: track servo and wear studyApplied Physics A, 1998
- 6-MHz 2-N/m piezoresistive atomic-force microscope cantilevers with INCISIVE tipsJournal of Microelectromechanical Systems, 1997
- Oxidation sharpening of silicon tipsJournal of Vacuum Science & Technology B: Microelectronics and Nanometer Structures, 1991