Determination of the Hugoniot elastic limits of differently treated 2024 Al specimens
- 14 July 1982
- journal article
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 15 (7), 1137-1142
- https://doi.org/10.1088/0022-3727/15/7/008
Abstract
Commercial Manganin gauges were used in a series of planar impact experiments in order to determine the Hugoniot elastic limits (HEL) of differently heat-treated 2024 aluminium samples. The gauges were used in an indirect configuration by which they were embedded in a soft backing material (polymethylmethacrylate (PMMA) in this case) at the back surface of the specimen. The resulting HEL values were compared with the corresponding yield stress values from uniaxial tension tests. It is found that the simple elastic relation between yield in uniaxial strain and uniaxial stress is obeyed. An additional measurement of the HEL of a pressurised sample also conforms with this simple relation.Keywords
This publication has 7 references indexed in Scilit:
- Release wave calibration of manganin gaugesJournal of Applied Physics, 1980
- Calibration of foil-like manganin gauges in planar shock wave experimentsJournal of Applied Physics, 1980
- The performance of a short-barrelled gas gunJournal of Physics E: Scientific Instruments, 1980
- Shock Wave Propagation in Layered CompositesJournal of Composite Materials, 1978
- Shock-Wave Studies of PMMA, Fused Silica, and SapphireJournal of Applied Physics, 1970
- Shock-Induced Dynamic Yielding in Copper Single CrystalsJournal of Applied Physics, 1969
- Shock Wave Compression of Hardened and Annealed 2024 AluminumJournal of Applied Physics, 1961