Tests of SEC Stability in High Flux Proton Beams
- 1 June 1979
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 26 (3), 3355-3357
- https://doi.org/10.1109/tns.1979.4330034
Abstract
The Secondary Emission Chamber (SEC) is used to measure the beam intensity in slow extracted beam channels of proton synchrotrons around the world. With the improvements in machine intensity, these monitors have been exposed to higher flux conditions than in the past. A change in sensitivity of up to 25% has been observed in the region around the beam spot. Using SEC's of special construction, a series of tests was performed at FNAL, BNL-AGS and CERN-PS. The results of these tests and conclusions about the construction of more stable SEC's are presented.Keywords
This publication has 3 references indexed in Scilit:
- MEASUREMENTS OF HIGH ENERGY PROTON FLUXES USING FOIL ACTIVATION TECHNIQUES (FAT)Published by Office of Scientific and Technical Information (OSTI) ,1977
- EVALUATION TESTS OF TWO SPECIAL SECONDARY EMISSION CHAMBERSPublished by Office of Scientific and Technical Information (OSTI) ,1977
- Factors influencing the stability of a secondary electron monitorNuclear Instruments and Methods, 1963