Properties of the Proportional (Geiger-Klemperer) Counter
- 1 July 1937
- journal article
- research article
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 8 (7), 254-258
- https://doi.org/10.1063/1.1752304
Abstract
A variety of different gases at different pressures have been introduced into a wire form proportional counter and the linearity of response over the entrance studied. It is found that this varies markedly with the nature and pressure of the gas, being very poor for gases which readily form negative ions and improving for almost all gases as the pressure is reduced. An incomplete explanation of the behavior of the counter in terms fo the formation of negative ions is given, which is useful as a qualitative guide. Suitable gases and pressures are recommended for various types of particle counting.This publication has 4 references indexed in Scilit:
- Artificial disintegration by radium C' α-particles-aluminium and magnesiumProceedings of the Royal Society of London. Series A, Containing Papers of a Mathematical and Physical Character, 1934
- Die künstliche Umwandlung des Magnesiums durch Polonium-α-TeilchenThe European Physical Journal A, 1934
- Zertrümmerungsversuche an Bor mit α-Strahlen von RaC′The European Physical Journal A, 1930
- Beitrag zur Wirkungsweise des SpitzenzählersThe European Physical Journal A, 1928