On the clinical spatial resolution achievable with protons and heavier charged particle radiotherapy beams
- 13 May 2009
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 54 (11), N205-N215
- https://doi.org/10.1088/0031-9155/54/11/n01
Abstract
The 'sub-millimetre precision' often claimed to be achievable in protons and light ion beam therapy is analysed using the Monte Carlo code SHIELD-HIT for a broad range of energies. Based on the range of possible values and uncertainties of the mean excitation energy of water and human tissues, as well as of the composition of organs and tissues, it is concluded that precision statements deserve careful reconsideration for treatment planning purposes. It is found that the range of I-values of water stated in ICRU reports 37, 49 and 73 (1984, 1993 and 2005) for the collision stopping power formulae, namely 67 eV, 75 eV and 80 eV, yields a spread of the depth of the Bragg peak of protons and heavier charged particles (carbon ions) of up to 5 or 6 mm, which is also found to be energy dependent due to other energy loss competing interaction mechanisms. The spread is similar in protons and in carbon ions having analogous practical range. Although accurate depth-dose distribution measurements in water can be used at the time of developing empirical dose calculation models, the energy dependence of the spread causes a substantial constraint. In the case of in vivo human tissues, where distribution measurements are not feasible, the problem poses a major limitation. In addition to the spread due to the currently accepted uncertainties of their I-values, a spread of the depth of the Bragg peak due to the varying compositions of soft tissues is also demonstrated, even for cases which could be considered practically identical in clinical practice. For these, the spreads found were similar to those of water or even larger, providing support to international recommendations advising that body-tissue compositions should not be given the standing of physical constants. The results show that it would be necessary to increase the margins of a clinical target volume, even in the case of a water phantom, due to an 'intrinsic basic physics uncertainty', adding to those margins usually considered in normal clinical practice due to anatomical or therapeutic strategy reasons. Individualized patient determination of tissue composition along the complete beam path, rather than CT Hounsfield numbers alone, would also probably be required even to reach 'sub-centimetre precision'.Keywords
This publication has 18 references indexed in Scilit:
- European boost for particle therapyNature, 2009
- Magical Protons?International Journal of Radiation Oncology*Biology*Physics, 2008
- Calculation of stopping power ratios for carbon ion dosimetryPhysics in Medicine & Biology, 2006
- Target volume dose considerations in proton beam treatment planning for lung tumorsMedical Physics, 2005
- How particle physics can be therapeuticPhysics World, 2003
- Relation between carbon ion ranges and x‐ray CT numbersMedical Physics, 2001
- Treatment planning for heavy-ion radiotherapy: physical beam model and dose optimizationPhysics in Medicine & Biology, 2000
- Tumor therapy with heavy charged particlesProgress in Particle and Nuclear Physics, 2000
- Energy loss of 70 MeV protons in elementsNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 1992
- Electron Pencil-Beam CalculationsPublished by Springer Nature ,1988