Electrophysiological study of transport systems in isolated perfused pancreatic ducts: properties of the basolateral membrane
- 1 January 1988
- journal article
- research article
- Published by Springer Nature in Pflügers Archiv - European Journal of Physiology
- Vol. 411 (1), 58-68
- https://doi.org/10.1007/bf00581647
Abstract
In order to study the mechanism of pancreatic HCO 3 − transport, a perfused preparation of isolated intra-and interlobular ducts (i.d. 20–40 μm) of rat pancreas was developed. Responses of the epithelium to changes in the bath ionic concentration and to addition of transport inhibitors was monitored by electrophysiological techniques. In this report some properties of the basolateral membrane of pancreatic duct cells are described. The transepithelial potential difference (PDte) in ducts bathed in HCO 3 − -free and HCO 3 − -containing solution was −0.8 and −2.6 mV, respectively. The equivalent short circuit current (Isc) under similar conditions was 26 and 50 μA·cm−2. The specific transepithelial resistance (Rte) was 88 Ωcm2. In control solutions the PD across the basolateral membrane (PDbl) was −63±1 mV (n=314). Ouabain (3 mmol/l) depolarized PDbl by 4.8±1.1 mV (n=6) within less than 10 s. When the bath K+ concentration was increased from 5 to 20 mmol/l, PDbl depolarized by 15.9±0.9 mV (n=50). The same K+ concentration step had no effect on PDbl if the ducts were exposed to Ba2+, a K+ channel blocker. Application of Ba2+ (1 mmol/l) alone depolarized PDbl by 26.4±1.4 mV (n=19), while another K+ channel blocker TEA+ (50 mmol/l) depolarized PDbl only by 7.7±2.0 mV (n=9). Addition of amiloride (1 mmol/l) to the bath caused 3–4 mV depolarization of PDbl. Furosemide (0.1 mmol/l) and SITS (0.1 mmol/l) had no effect on PDbl. An increase in the bath HCO 3 − concentration from 0 to 25 mmol/l produced fast and sustained depolarization of PDbl by 8.5±1.0 mV (n=149). It was investigated whether the effect of HCO 3 − was due to a Na++-dependent transport mechanism on the basolateral membrane, where the ion complex transferred into the cell would be positively charged, or whether it was due to decreased K+ conductance caused by lowered intracellular pH. Experiments showed that the HCO 3 − effect was present even when the bath Na+ concentration was reduced to a nominal value of 0 mmol/l. Similarly, the HCO 3 − effect remained unchanged after Ba2+ (5 mmol/l) was added to the bath. The results indicate that on the basolateral membrane of duct cells there is a ouabain sensitive (Na++K+)-ATPase, a Ba2+ sensitive K+ conductance and an amiloride sensitive Na+/H+ antiport. The HCO 3 − effect on PDbl is most likely due to rheogenic anion exit across the luminal membrane.Keywords
This publication has 52 references indexed in Scilit:
- Lack of effect of amiloride, furosemide, bumetanide and triamterene on pancreatic NaHCO3 secretion in pigsActa Physiologica Scandinavica, 1986
- Evidence for coupled transport of bicarbonate and sodium in cultured bovine corneal endothelial cellsThe Journal of Membrane Biology, 1984
- Regulation of the basolateral potassium conductance of theNecturus proximal tubuleThe Journal of Membrane Biology, 1984
- A LIGHT AND ELECTRON MICROSCOPIC STUDY ON THE PANCREATIC DUCTAL SYSTEMActa Pathologica Japonica, 1983
- Transport of H+ and of ionic weak acids and basesThe Journal of Membrane Biology, 1983
- Properties of the lumen membrane of the cortical thick ascending limb of Henle's loop of rabbit kidneyPflügers Archiv - European Journal of Physiology, 1983
- Ionic transport mechanisms underlying fluid secretion by the pancreasPhilosophical Transactions of the Royal Society of London. B, Biological Sciences, 1981
- Interaction of ouabain with the Na(+) pump in intact epithelial cellsThe Journal of cell biology, 1981
- BICARBONATE TRANSPORT IN THE EXOCRINE PANCREASAnnals of the New York Academy of Sciences, 1980
- Influence of bicarbonate-CO2- and glycodiazine buffer on the secretion of the isolated cat's pancreasPflügers Archiv - European Journal of Physiology, 1971