Catheter ablation of the atrioventricular junction with radiofrequency energy.
- 1 December 1989
- journal article
- research article
- Published by Wolters Kluwer Health in Circulation
- Vol. 80 (6), 1527-1535
- https://doi.org/10.1161/01.cir.80.6.1527
Abstract
Catheter ablation of the atrioventricular junction using direct-current defibrillator discharges requires general anesthesia and may have serious side effects. Sixteen patients with drug-refractory supraventricular tachycardia underwent catheter ablation of the atrioventricular junction using radiofrequency energy. A standard 7F quadripolar electrode catheter was positioned to record the largest unipolar His potential (580 +/- 640 microV) from the distal electrode. An electrocoagulator (Microvasive Bicap 4005) supplied continuous, unmodulated energy at 550 kHz. One to 14 applications of radiofrequency current were delivered between the distal electrode and a large-diameter chest wall electrode. Transient, mild chest discomfort was reported by seven of 16 patients. None had significant arrhythmias or blood pressure changes during radiofrequency ablation. Complete atrioventricular block was produced in nine of 16 patients and high-grade second-degree atrioventricular block was produced in one patient with radiofrequency current. Attenuated His bundle electrograms could still be recorded in the remaining six patients, four of whom underwent successful atrioventricular junctional ablation using direct-current shock during the same session. Atrioventricular block persisted in all 10 patients successfully treated with radiofrequency ablation during a mean follow-up of 4.2 months. Compared with a group of historic control subjects treated with direct-current shock ablation, the 10 patients successfully treated with radiofrequency current had significantly less creatine kinase-MB isoenzyme release (5.7 +/- 5.1 vs. 22 +/- 13 IU, p = 0.006). A junctional escape rhythm was present in all patients after radiofrequency-induced atrioventricular block. In contrast, three of 10 control patients had an idioventricular escape after direct current shock ablation, and four patients had no escape rhythm at all.(ABSTRACT TRUNCATED AT 250 WORDS)This publication has 10 references indexed in Scilit:
- Radiofrequency Catheter Ablation of the Left and Right Ventricles: Anatomic and Electrophysiologic ObservationsPacing and Clinical Electrophysiology, 1988
- Bioelectric Effects of High-Energy, Electrical DischargesPublished by Springer Nature ,1988
- Proarrhythmic effects of ventricular electrical catheter ablation in dogsJournal of the American College of Cardiology, 1987
- Closed chest catheter desiccation of the atrioventricular junction using radiofrequency energy—A new method of catheter ablationJournal of the American College of Cardiology, 1987
- CLOSED-CHEST ATRIOVENTRICULAR JUNCTION ABLATION BY HIGH-FREQUENCY ENERGY TRANSCATHETER DESICCATIONThe Lancet, 1986
- Catheter Ablation for Patients with Cardiac ArrhythmiasPacing and Clinical Electrophysiology, 1986
- Sequelae of left ventricular electrical endocardial ablationJournal of the American College of Cardiology, 1985
- Catheter ablation of the atrioventricular junction: a report of the percutaneous mapping and ablation registry.Circulation, 1984
- Catheter Technique for Closed-Chest Ablation of the Atrioventricular Conduction SystemNew England Journal of Medicine, 1982