Validation of Quantitative Intraoperative Transesophageal Echocardiography
Open Access
- 1 October 1986
- journal article
- research article
- Published by Wolters Kluwer Health in Anesthesiology
- Vol. 65 (4), 418-421
- https://doi.org/10.1097/00000542-198610000-00012
Abstract
Transesophageal echocardiography (TEE) is a new monitoring technique that images the heart and provides information on regional wall motion and left ventricular filling. However, despite it''s potential for inaccuracy due to it''s retrocardiac position and angulation, TEE has not been validated by another imaging technique. Using direct on-heart echocardiography (OHE) as a standard, the authors evaluated the ability of TEE to measure accurately left ventricular end-diastolic area (EDa), end-systolic area (ESa), and ejection fraction area (EFa). Ten patients with coronary artery disease without evidence of valvular dysfunction undergoing myocardial revascularization were studied. A Diasonics 3.5 MHz two-dimensional TEE probe was introduced into each patient''s esophagus and positioned to obtain a view equivalent to the parasternal short-axis projection. A similar view was obtained by OHE using a sterilely prepared 3 MHz ATL probe placed on either the pericardium or epicardium. In each patient, immediately prior to and after pericardiotomy, both transesophageal and on-heart short-axis views at the level of the papillary muscles were obtained. Using a dedicated Diasonics computer echoanalyzer, EDa and ESa from four consecutive cardiac cycles were outlined with a light pen and averaged ETa was calculated by the formula EFa = (EDa-ESa)/EDa. Seventeen comparable transesophageal and on-heart echocardiograms were obtained. ESa by TEE correlated well with ESa by OHE (15.13 .+-. 9.62 cm2 vs. 14.92 .+-. 10.53 cm2; r = 0.94). Similar results were obtained for EDa (27.75 .+-. 9.88 cm2 vs. 30.40 .+-. 13.99 cm2; r = 0.88) and EFa (0.49 .+-. 0.17 vs. 0.54 .+-. 0.13; r = 0.92). TEE can accurately assess left ventricular filing and ejection.This publication has 4 references indexed in Scilit:
- Immediate improvement of dysfunctional myocardial segments after coronary revascularization: Detection by intraoperative transesophageal echocardiographyJournal of the American College of Cardiology, 1984
- Transesophageal two-dimensional echocardiography: Comparison of ultrasonic and anatomic sectionsThe American Journal of Cardiology, 1984
- Left ventricular ejection fraction during cardiac surgery: a two-dimensional echocardiographic study.Circulation, 1983
- Transoesophageal cross-sectional echocardiography with a phased array transducer system. Technique and initial clinical results.Heart, 1982