Four Years’ Experience With a Miniaturized Extracorporeal Circulation System and Its Influence on Clinical Outcome
Open Access
- 19 November 2004
- journal article
- Published by Wiley in Artificial Organs
- Vol. 28 (12), 1082-1088
- https://doi.org/10.1111/j.1525-1594.2004.00030.x
Abstract
It has been suggested that the morbidity associated with cardiopulmonary bypass can be attributed in part to the blood–material and blood–air interactions in the extracorporeal circulation (ECC). A recently introduced minimized ECC-system (MECC System) should be able to reduce these negative effects associated with ECC. A retrospective analysis was performed comprising 485 patients who were operated on for elective coronary artery bypass grafting (CABG) using the MECC System with intermittent antegrade warm blood cardioplegia (group 1) from January 2000 to February 2004. A control group consisted of 485 patients (group 2) undergoing elective CABG in the same period using a conventional ECC and cold crystalloid cardioplegia. There were no significant differences between the two groups in terms of the duration of intubation following surgery, the length of intensive care unit-stay and the total hospital stay. Although the 30-day mortality was similar between the two groups, the incidence of postoperative complications and the perioperative use of blood products were significantly higher in the control group compared to the MECC group. The MECC System may serve as an alternative and less invasive approach to conventional ECC.Keywords
This publication has 24 references indexed in Scilit:
- Cardiac Surgery in Germany during 2001: A Report by the German Society for Thoracic and Cardiovascular SurgeryThe Thoracic and Cardiovascular Surgeon, 2002
- Clinical evaluation of Duraflo® II heparin treated extracorporeal circulation circuits (2nd version) The European working group on heparin coated extracorporeal circulation circuitsEuropean Journal of Cardio-Thoracic Surgery, 1997
- Centrifugal pump and heparin coating improves cardiopulmonary bypass biocompatibilityThe Annals of Thoracic Surgery, 1996
- Coronary bypass graft fate and patient outcome: Angiographic follow-up of 5,065 grafts related to survival and reoperation in 1,388 patients during 25 yearsJournal of the American College of Cardiology, 1996
- Coronary Bypass Graft Fate and Patient Outcome: Angiographic Follow-Up of 5,065 Grafts Related to Survival and Reoperation in 1,388 Patients During 25 YearsJournal of the American College of Cardiology, 1996
- Biocompatibility of heparin-coated extracorporeal bypass circuits: A randomized, masked clinical trialThe Journal of Thoracic and Cardiovascular Surgery, 1996
- Complement and granulocyte activation in two different types of heparinized extracorporeal circuitsThe Journal of Thoracic and Cardiovascular Surgery, 1995
- Systemic blood activation with open and closed venous reservoirsThe Annals of Thoracic Surgery, 1995
- Intermittent antegrade warm blood cardioplegiaThe Annals of Thoracic Surgery, 1995
- Coronary artery bypass grafting: The Society of Thoracic Surgeons National Database experienceThe Annals of Thoracic Surgery, 1994