Quantitative autoradiography of central neurotransmitter receptors: methodological and statistical aspects with special reference to computer-assisted image analysis
- 1 October 1986
- journal article
- Published by Wiley in Acta Physiologica Scandinavica
- Vol. 128 (2), 129-146
- https://doi.org/10.1111/j.1748-1716.1986.tb07960.x
Abstract
In the last few years, quantitative receptor autoradiography has been extensively employed to study the distribution and the functional role of area-specific transmitter receptors in the central nervous system. In the present paper we have developed quantitative methodologies for the analysis of autoradiograms using computerized image analysers coupled with standard TV camera input for the microdensitometrical evaluations. These procedures include the assessment of the film response to radioactivity using appropriate standards calibrated according to brain tissue quenching and non-linear conversion of density measurements in radioactivity values adopting the best mathematical model fitting to give as little variability as possible in the transformations. The reliability of the proposed approach has also been evaluated by means of a computer-assisted Monte Carlo simulation and parallel biochemical determinations.Keywords
This publication has 14 references indexed in Scilit:
- Quantitative film autoradiography for tritium: Methodological considerationsBrain Research, 1985
- Basic Concepts to Analyze Binding Data Using Personal Computers: The “RECEPT” programPublished by Springer Nature ,1984
- NL-FIT: A microcomputer program for non-linear fittingComputer Programs in Biomedicine, 1983
- Model Testing in Radioligand/Receptor Interaction by Monte Carlo SimulationJournal of Receptor Research, 1983
- Quantitative receptor autoradiography using [3H]Ultrofilm: application to multiple benzodiazepine receptorsJournal of Neuroscience Methods, 1982
- Brain (Na+, K+)‐ATPase and Noradrenergic Activity: Effects of Hyperinnervation and Denervation on High‐Affinity Ouabain BindingJournal of Neurochemistry, 1982
- SPBS: Statistical programs for biological sciences Minicomputer software for applying routine biostatistical methodsComputer Programs in Biomedicine, 1982
- Quantitative densitometry of neurotransmitter receptorsJournal of Neuroscience Methods, 1982
- Quantitative measurement of local cerebral metabolic rate for glucose utilizing tritiated 2-deoxyglucoseBrain Research, 1981
- LIGAND: A versatile computerized approach for characterization of ligand-binding systemsAnalytical Biochemistry, 1980