Abstract
Flow visualization has been used quantitatively to determine the flow relative to a piston and a free surface started from rest. The discharge of water from a cylindrical reservoir was investigated. Flow with a free surface started from rest was found to have a critical Reynolds number (based on tube diameter and surface speed) of about 450 above which a ring vortex was produced just below the surface.Measurements at Reynolds numbers of 525 and 1200 were compared with computations made by the methods described in Part 1. The computed drift of tracer particles agreed well with observed values. The largest discrepancies occurred in the radial component of the drift in the early stages of the motion and amounted to 2½% of the tube diameter.