Fetal doses to pregnant patients from CT with tube current modulation calculated using Monte Carlo simulations and realistic phantoms
- 6 December 2012
- journal article
- research article
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 155 (1), 64-72
- https://doi.org/10.1093/rpd/ncs312
Abstract
To investigate the radiation dose to the fetus using retrospective tube current modulation (TCM) data selected from archived clinical records. This paper describes the calculation of fetal doses using retrospective TCM data and Monte Carlo (MC) simulations. Three TCM schemes were adopted for use with three pregnant patient phantoms. MC simulations were used to model CT scanners, TCM schemes and pregnant patients. Comparisons between organ doses from TCM schemes and those from non-TCM schemes show that these three TCM schemes reduced fetal doses by 14, 18 and 25 %, respectively. These organ doses were also compared with those from ImPACT calculation. It is found that the difference between the calculated fetal dose and the ImPACT reported dose is as high as 46 %. This work demonstrates methods to study organ doses from various TCM protocols and potential ways to improve the accuracy of CT dose calculation for pregnant patients.Keywords
This publication has 21 references indexed in Scilit:
- Radiation Management for Interventions Using Fluoroscopic or Computed Tomographic Guidance during Pregnancy: A Joint Guideline of the Society of Interventional Radiology and the Cardiovascular and Interventional Radiological Society of Europe with Endorsement by the Canadian Interventional Radiology AssociationJournal of Vascular and Interventional Radiology, 2011
- Comparison of Angular and Combined Automatic Tube Current Modulation Techniques with Constant Tube Current CT of the Abdomen and PelvisAmerican Journal of Roentgenology, 2006
- A Monte Carlo based method to estimate radiation dose from multidetector CT (MDCT): cylindrical and anthropomorphic phantomsPhysics in Medicine & Biology, 2005
- 5. Optimization of Image Quality by CT Scanner Automatic Exposure Control Systems(Symposium Rightness of Examination at X-ray CT : To Make Up the Guideline onto Evidence-Based Medicine, The 61st Annual Scientific Congress)Japanese Journal of Radiological Technology, 2005
- Embryo/Fetus Radiation Dose and Risk from Dual X-ray Absorptiometry ExaminationsOsteoporosis International, 2002
- Dose reduction on GE CT scannersPediatric Radiology, 2002
- Basic anatomical and physiological data for use in radiological protection: reference values. A report of age- and gender-related differences in the anatomical and physiological characteristics of reference individuals. ICRP Publication 89.2002
- Dose reduction in CT by anatomically adapted tube current modulation. I. Simulation studiesMedical Physics, 1999
- Das „Smart-Scan”-Verfahren der Spiral-Computertomographie: Eine neue Methode der DosisreduktionRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 1996
- Estimated fetal radiation dose from multislice CT studies.American Journal of Roentgenology, 1990