Regularization Techniques for ECG Imaging during Atrial Fibrillation: A Computational Study
Open Access
- 14 October 2016
- journal article
- research article
- Published by Frontiers Media SA in Frontiers in Physiology
- Vol. 7, 466
- https://doi.org/10.3389/fphys.2016.00466
Abstract
The inverse problem of electrocardiography is usually analyzed during stationary rhythms. However, the performance of the regularization methods under fibrillatory conditions has not been fully studied. In this work, we assessed different regularization techniques during atrial fibrillation (AF) for estimating four target parameters, namely, epicardial potentials, dominant frequency (DF), phase maps, and singularity point (SP) location. We use a realistic mathematical model of atria and torso anatomy with three different electrical activity patterns (i.e. sinus rhythm, simple AF and complex AF). Body surface potentials (BSP) were simulated using Boundary Element Method and corrupted with white Gaussian noise of different powers. Noisy BSPs were used to obtain the epicardial potentials on the atrial surface, using fourteen different regularization techniques. DF, phase maps and SP location were computed from estimated epicardial potentials. Inverse solutions were evaluated using a set of performance metrics adapted to each clinical target. For the case of SP location, an assessment methodology based on the spatial mass function of the SP location and four spatial error metrics was proposed. The role of the regularization parameter for Tikhonov-based methods, and the effect of noise level and imperfections in the knowledge of the transfer matrix were also addressed. Results showed that the Bayes maximum-a-posteriori method clearly outperforms the rest of the techniques but requires a priori information about the epicardial potentials. Among the purely non-invasive techniques, Tikhonov-based methods performed as well as more complex techniques in realistic fibrillatory conditions, with a slight gain between 0.02 and 0.2 in terms of the correlation coefficient. Also, the use of a constant regularization parameter may be advisable since the performance was similar to that obtained with a variable parameter (indeed there was no difference for the zero-order Tikhonov method in complex fibrillatory conditions). Regarding the different targets, DF and SP location estimation were more robust with respect to pattern complexity and noise, and most algorithms provided a reasonable estimation of these parameters, even when the epicardial potentials estimation was inaccurate. Finally, the proposed evaluation procedure and metrics represent a suitable framework for techniques benchmarking and provide useful insights for the clinical practice.Keywords
Funding Information
- Ministerio de Economía y Competitividad (TEC2013-46067-R)
This publication has 50 references indexed in Scilit:
- Noninvasive Panoramic Mapping of Human Atrial Fibrillation Mechanisms: A Feasibility ReportJournal of Cardiovascular Electrophysiology, 2012
- Treatment of Atrial Fibrillation by the Ablation of Localized SourcesJournal of the American College of Cardiology, 2012
- The Electrophysiological Cardiac Ventricular Substrate in Patients After Myocardial InfarctionJournal of the American College of Cardiology, 2011
- Noninvasive Characterization of Epicardial Activation in Humans With Diverse Atrial Fibrillation PatternsCirculation, 2010
- Non-Invasive Imaging of Cardiac Activation and RecoveryAnnals of Biomedical Engineering, 2009
- Application of L1-Norm Regularization to Epicardial Potential Solution of the Inverse Electrocardiography ProblemAnnals of Biomedical Engineering, 2009
- Rotor meandering contributes to irregularity in electrograms during atrial fibrillationHeart Rhythm, 2008
- The forward and inverse problems of electrocardiographyIEEE Engineering in Medicine and Biology Magazine, 1998
- Recent progress in inverse problems in electrocardiologyIEEE Engineering in Medicine and Biology Magazine, 1998
- Regional regularization of the electrocardiographic inverse problem: a model study using spherical geometryIEEE Transactions on Biomedical Engineering, 1997