Quantitative Thin-Layer Chromatography/Mass Spectrometry Analysis of Caffeine Using a Surface Sampling Probe Electrospray Ionization Tandem Mass Spectrometry System
- 27 May 2005
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 77 (14), 4385-4389
- https://doi.org/10.1021/ac050488s
Abstract
Quantitative determination of caffeine on reversed-phase C8 thin-layer chromatography plates using a surface sampling electrospray ionization system with tandem mass spectrometry detection is reported. The thin-layer chromatography/electrospray tandem mass spectrometry method employed a deuterium-labeled caffeine internal standard and selected reaction monitoring detection. Up to nine parallel caffeine bands on a single plate were sampled in a single surface scanning experiment requiring 35 min at a surface scan rate of 44 μm/s. A reversed-phase HPLC/UV caffeine assay was developed in parallel to assess the mass spectrometry method performance. Limits of detection for the HPLC/UV and thin-layer chromatography/electrospray tandem mass spectrometry methods determined from the calibration curve statistics were 0.20 ng injected (0.50 μL) and 1.0 ng spotted on the plate, respectively. Spike recoveries with standards and real samples ranged between 97 and 106% for both methods. The caffeine content of three diet soft drinks (Diet Coke, Diet Cherry Coke, Diet Pepsi) and three diet sport drinks (Diet Turbo Tea, Speed Stack Grape, Speed Stack Fruit Punch) was measured. The HPLC/UV and mass spectrometry determinations were in general agreement, and these values were consistent with the quoted values for two of the three diet colas. In the case of Diet Cherry Coke and the diet sports drinks, the determined caffeine amounts using both methods were consistently higher (by ∼8% or more) than the literature values.Keywords
This publication has 9 references indexed in Scilit:
- Electrospray ionization mass spectrometric characterization and quantitation of xanthine derivatives using isotopically labelled analogues: an application for equine doping control analysisRapid Communications in Mass Spectrometry, 2004
- Quantitative determination of Piroxicam by TLC–MALDI TOF MSJournal of Pharmaceutical and Biomedical Analysis, 2004
- Thin-layer chromatography: challenges and opportunitiesJournal of Chromatography A, 2003
- Planar chromatography at the turn of the centuryJournal of Chromatography A, 1999
- The state of the art in thin-layer chromatography–mass spectrometry: a critical appraisalJournal of Chromatography A, 1999
- Direct Quantitative Analysis from Thin-Layer Chromatography Plates Using Matrix-Assisted Laser Desorption/Ionization Mass SpectrometryApplied Spectroscopy, 1996
- Mass spectrometric detectors for samples separated by planar electrophoresisJournal of Chromatography A, 1995
- Quantitative analysis by thin-layer chromatography with secondary ion mass spectrometryChromatographia, 1991
- Examination of the automated solute-independent calibration techniqueAnalytical Chemistry, 1989