Importance of clot structure in gradient‐echo magnetic resonance imaging of hematoma
- 1 November 1996
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 6 (6), 878-883
- https://doi.org/10.1002/jmri.1880060607
Abstract
The MR appearance of clots with different internal structures was compared on gradient-echo (GE) and spin-echo (SE) images. After MR imaging, clots were submitted for histological analysis to allow direct correlation of clot structure with MR image intensity. Normal heterogeneous clots (containing entrapped serum) were hypointense compared to both unclotted blood (Hct 45) and brain on GE MR images. Homogeneous (serum-poor) clots and settled blood were hyperintense to unclotted blood and isointense or hyperintense to brain. These results indicate that the GE technique is quite sensitive to the physical inhomogeneity created (at the voxel level) when blood forms an inhomogeneous clot containing relatively large islands of red blood cells (RBCs) surrounded by lakes of serum. The effect of the different possible clot structures on GE signal intensity thus provides an etiology for the previously unexplained observations of hemorrhage with high signal intensity on GE MR images.Keywords
This publication has 26 references indexed in Scilit:
- Change in red blood cell relaxation with hydration: Application to MR imaging of hemorrhageJournal of Magnetic Resonance Imaging, 1992
- Mottled MR Appearance of a Hyperacute Intracerebral Hemorrhage at 0.5 TJournal of Computer Assisted Tomography, 1990
- NMR water‐proton spin‐lattice relaxation time of human red blood cells and red blood cell suspensionsFEBS Letters, 1988
- NMR Relaxation Times of BloodJournal of Computer Assisted Tomography, 1987
- Clinical Magnetic Susceptibility Mapping of the BrainJournal of Computer Assisted Tomography, 1987
- Chronological changes in spontaneous intracerebral hematoma--an experimental and clinical study.Stroke, 1985
- Determinants of Proton Relaxation Rates in TissueMagnetic Resonance in Medicine, 1984
- Oxygenation dependence of the transverse relaxation time of water protons in whole blood at high fieldBiochimica et Biophysica Acta (BBA) - General Subjects, 1982
- Water exchange across red cell membranes: II. Measurement by nuclear magnetic resonanceT 1,T 2, andT 12 hybrid relaxation. The effects of osmolarity, cell volume, and mediumThe Journal of Membrane Biology, 1978
- Magnetic-field-dependent water proton spin-lattice relaxation rates of hemoglobin solutions and whole bloodJournal of Magnetic Resonance (1969), 1974