Selective Stimulation of Cat Sciatic Nerve Using an Array of Varying-Length Microelectrodes
- 1 April 2001
- journal article
- research article
- Published by American Physiological Society in Journal of Neurophysiology
- Vol. 85 (4), 1585-1594
- https://doi.org/10.1152/jn.2001.85.4.1585
Abstract
Restoration of motor function to individuals who have had spinal cord injuries or stroke has been hampered by the lack of an interface to the peripheral nervous system. A suitable interface should provide selective stimulation of a large number of individual muscle groups with graded recruitment of force. We have developed a new neural interface, the Utah Slanted Electrode Array (USEA), that was designed to be implanted into peripheral nerves. Its goal is to provide such an interface that could be useful in rehabilitation as well as neuroscience applications. In this study, the stimulation capabilities of the USEA were evaluated in acute experiments in cat sciatic nerve. The recruitment properties and the selectivity of stimulation were examined by determining the target muscles excited by stimulation via each of the 100 electrodes in the array and using force transducers to record the force produced in these muscles. It is shown in the results that groups of up to 15 electrodes were inserted into individual fascicles. Stimulation slightly above threshold was selective to one muscle group for most individual electrodes. At higher currents, co-activation of agonist but not antagonist muscles was observed in some instances. Recruitment curves for the electrode array were broader with twitch thresholds starting at much lower currents than for cuff electrodes. In these experiments, it is also shown that certain combinations of electrode pairs, inserted into an individual fascicle, excite fiber populations with substantial overlap, whereas other pairs appear to address independent populations. We conclude that the USEA permits more selective stimulation at much lower current intensities with more graded recruitment of individual muscles than is achieved by conventional cuff electrodes.Keywords
This publication has 37 references indexed in Scilit:
- A multielectrode array for intrafascicular recording and stimulation in sciatic nerve of catsBrain Research Bulletin, 2000
- New Easy to Install Nerve Cuff Electrode Using Shape Memory Alloy ArmatureArtificial Organs, 1999
- Implantable electrode lead in a growing limbIEEE Transactions on Rehabilitation Engineering, 1999
- COMPARISON OF DISCOMFORT ASSOCIATED WITH SURFACE AND PERCUTANEOUS INTRAMUSCULAR ELECTRICAL STIMULATION FOR PERSONS WITH CHRONIC HEMIPLEGIA1American Journal of Physical Medicine & Rehabilitation, 1998
- Long-term biocompatibility of a miniature stimulator implanted in feline hind limb musclesIEEE Transactions on Biomedical Engineering, 1998
- Effects of regional stimulation using a miniature stimulator implanted in feline posterior biceps femorisIEEE Transactions on Biomedical Engineering, 1998
- Extraction forces and tissue changes during explant of CWRU-type intramuscular electrodes from rat gastrocnemiusAnnals of Biomedical Engineering, 1997
- Peripheral Nerve Stimulation for Restoration of Motor FunctionJournal Of Clinical Neurophysiology, 1997
- Acute and chronic implantation of coiled wire intraneural electrodes during cyclical electrical stimulationAnnals of Biomedical Engineering, 1985
- The effect of activation history on tension production by individual muscle unitsBrain Research, 1976