Measurement of the saturation magnetostriction constant of amorphous wire
- 1 May 1990
- journal article
- research article
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 67 (9), 4986-4988
- https://doi.org/10.1063/1.344698
Abstract
Measurement of the magnetostriction constant of amorphous wire by conventional techniques is very difficult because of its small diameter. However, accurate determination of the magnetostriction constant is important in the study of amorphous wires. Here the saturation magnetostriction constant (λs) for a low‐magnetostriction amorphous wire of nominal composition (Fe6.3Co92.7Nb1)77.5Si7.5B15 has been determined by means of the small‐angle magnetization‐rotation method. λs has been evaluated to be 2.1×10−7 for its as‐received state. The dependence of thermal treatment is also reported.Keywords
This publication has 4 references indexed in Scilit:
- Magnetostriction measurements for amorphous wiresIEEE Transactions on Magnetics, 1989
- Influence of the anisotropy on the “SAMR” method for measuring magnetostriction in amorphous ribbonsJournal of Magnetism and Magnetic Materials, 1986
- Production of Metal Filament by In-Rotating-Water Spinning MethodJournal of the Japan Institute of Metals and Materials, 1981
- Measurement of saturation magnetostriction of a thin amorphous ribbon by means of small-angle magnetization rotationIEEE Transactions on Magnetics, 1980