A New Method of Paired Thyrotropin Assay as a Screening Test for Neonatal Hypothyroidism*
- 1 November 1978
- journal article
- research article
- Published by The Endocrine Society in Journal of Clinical Endocrinology & Metabolism
- Vol. 47 (5), 1028-1033
- https://doi.org/10.1210/jcem-47-5-1028
Abstract
A simple and reliable method of paired TSH assay was developed and used in screening for neonatal primary hypothyroidism. In this method, a paired assay is first done. Equal parts of the extracts of dried blood spots on filter paper (9 mm diameter) from two infants 4–7 days old are combined and assayed for TSH by double antibody RIA. If the value obtained is over the cut-off point, the extracts are assayed separately for TSH in a second assay to identify the abnormal sample. Two systems, A and B, with different cutoff points were tested. On the basis of reference blood samples (serum levels of TSH, 80 μU/ml in system A and 40 μU/ml in system B), the cut-off point was selected as follows: upper 5 (A) or 4 (B) percentile in the paired assay and values of reference blood samples in the second individual assay. Four cases (2 in A and 2 in B) of neonatal primary hypothyroidism were found among 25 infants (23 in A and 2 in B) who were recalled from a general population of 41,400 infants (24,200 in A and 17,200 in B) by 22,700 assays. This paired TSH assay system saves labor and expense for screening neonatal hypothyroidism.Keywords
This publication has 2 references indexed in Scilit: