Positive and negative dysphotopsia in patients with acrylic intraocular lenses
- 1 September 2000
- journal article
- case report
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 26 (9), 1346-1355
- https://doi.org/10.1016/s0886-3350(00)00611-8
Abstract
To report the incidence, management, and prevention of patient reports of glare and streaks around a point source of light or a dark shadow in the temporal field of vision after acrylic intraocular lens (IOL) implantation. A private practice. Cases in which patients complained vigorously of dysphotopsia were catalogued prospectively during the implantation experience in 6668 consecutive eyes having surgery between January 1995 and June 1999. The techniques of topical–intracameral anesthesia, temporal clear corneal incisions, and phacoemulsification were used in all cases. Alternate IOL styles were selected for use from July 1999 to April 2000. Fourteen cases (0.2%) were identified. The complaints resolved in 1, were diminished in 1, and were tolerated without change in 7. Five eyes of 4 patients required IOL exchange with capsular bag placement of a poly(methyl methacrylate) (PMMA) or silicone lens for resolution of symptoms. Selecting alternate IOL styles reduced the incidence of dysphotopsia. Glare and streaks from a point source of light represent positive photic expressions of dysphotopsia, and temporal dark shadows represent similar negative photic expressions. Both appear to be associated with shiny square-edge optics made of high-refractive-index acrylic polymer. Intraocular lenses of PMMA and silicone with rounded edges, along with square-edge acrylic IOLs with nonreflective edges, appear less likely to cause clinically significant pseudophakic dysphotopsia.Keywords
This publication has 16 references indexed in Scilit:
- Analysis of edge glare phenomena in intraocular lens edge designsJournal of Cataract & Refractive Surgery, 1999
- Update on fixation of rigid and foldable posterior chamber intraocular lenses. part II: choosing the correct haptic fixation and intraocular lens design to help eradicate posterior capsule opacificationOphthalmology, 1999
- Preventing posterior capsule opacification by creating a discontinuous sharp bend in the capsuleJournal of Cataract & Refractive Surgery, 1999
- Quantitative Comparison of Posterior Capsule Opacification After Polymethylmethacrylate, Silicone, and Soft Acrylic Intraocular Lens ImplantationArchives of Ophthalmology (1950), 1998
- Relationship between intraocular lens biomaterials and posterior capsule opacificationJournal of Cataract & Refractive Surgery, 1998
- Reduction in the Area of the Anterior Capsule Opening After Polymethylmethacrylate, Silicone, and Soft Acrylic Intraocular Lens ImplantationAmerican Journal of Ophthalmology, 1997
- Photic phenomena after phacoemulsification and posterior chamber lens implantation of various optic sizesJournal of Cataract & Refractive Surgery, 1994
- Undesired light images associated with ovoid intraocular lensesJournal of Cataract & Refractive Surgery, 1993
- The Lens Opacities Classification System IIIArchives of Ophthalmology (1950), 1993
- Evaluating the intraocular lens opticSurvey of Ophthalmology, 1986