Series shunt evaluation of polyurethane vascular graft materials in chronically AV‐shunted canines
- 1 January 1990
- journal article
- research article
- Published by Wiley in Journal of Biomedical Materials Research
- Vol. 24 (1), 107-129
- https://doi.org/10.1002/jbm.820240110
Abstract
Well characterized, laboratory‐synthesized polymeric materials which have been extensively tested for biocompatibility via initial platelet and protein deposition in an acute ex vivo canine model were placed as interpositional series shunts in canines with chronically implanted iliac arteriovenous shunts ex vivo. Platelet deposition was measured on a base polyurethane block copolymer, a sulfonated ionic derivative, an alkyl grafted (C18) derivative, Biomer, polyethylene, and polydimethylsiloxane for 24 h using radiolabeled platelets. Platelet survival and in vitro aggregation were determined to investigate the effects of the shunting pprocedure on experimental animals. The viability of adopting a chronic arteriovenous (iliac) shunted canine model for use with series shunts to evaluate polyurethanes having applications as materials in vascular graft construction was investigated and the results compared with acute model data.This publication has 21 references indexed in Scilit:
- Effects of alkyl grafting on surface properties and blood compatibility of polyurethane block copolymersJournal of Biomedical Materials Research, 1987
- Ionic Polyurethanes: Surface and Blood-Contacting PropertiesMRS Proceedings, 1987
- Solid surface tension: The interpretation of contact angles by the equation of state approach and the theory of surface tension componentsLangmuir, 1986
- The effect of predetermined thrombotic potential of the recipient on small-caliber graft performanceJournal of Vascular Surgery, 1986
- Platelet interactions with Dacron vascular grafts. A model of acute thrombosis in baboons.Arteriosclerosis: An Official Journal of the American Heart Association, Inc., 1985
- Parallel flow arteriovenous shunt for the ex vivo evaluation of heparinized materialsJournal of Biomedical Materials Research, 1985
- A canine ex vivo series shunt for evaluating thrombus deposition on polymer surfacesJournal of Biomedical Materials Research, 1984
- Design criteria for percutaneous devicesJournal of Biomedical Materials Research, 1984
- Direct in vivo study of flowing blood-artificial surface interactions — An original application of dynamic isotopic techniquesThe International Journal of Applied Radiation and Isotopes, 1980
- Arterio-venous shunt with percutaneous leads in calves for long-termin vivotesting of blood-contact materialsJournal of Biomedical Materials Research, 1978