Distributions of decayed nuclei generated in the and targets by the target nuclear fragment reaction using therapeutic MONO and SOBP proton beam
- 25 March 2005
- journal article
- radiation therapy-physics
- Published by Wiley in Medical Physics
- Vol. 32 (4), 1070-1082
- https://doi.org/10.1118/1.1879692
Abstract
In proton radiotherapy, the irradiation dose can be concentrated on a tumor. To use this radiotherapy efficiently in the clinical field, it is necessary to evaluate the proton‐irradiated area and condition. The proton‐irradiated area can be confirmed by coincidence detection of pair annihilation gamma rays from decayed nuclei generated by target nuclear fragment reaction of irradiated proton nuclei and nuclei in the irradiation target. In this study, we performed experiments of proton irradiation to a polyethylene target containing nuclei, which is a major component of the human body, and a gelatinous water target containing nuclei at different proton irradiation energy levels under different beam conditions of mono‐energetic Bragg peak and spread‐out Bragg peak. The distribution of the activity in the target after proton irradiation was measured by a positron emission tomography (PET) apparatus, and compared with the calculated distribution. The temporal dependence of the activity distribution during the period between the completion of proton irradiation and the start of measurement by the PET apparatus was examined. The activity by clinical proton irradiation was in the PE target and in the water target, indicating that the intensity was sufficient for the evaluation of the distribution. The range of the activity distribution against the physical range was short (several millimeter water equivalent length), indicating the presence of target dependence. The range difference in the water target was slightly large with time dependence until the start of measurement. The difference of the lateral widths with full width half at maximum in the distributions of the measured irradiated dose and activity was within .Keywords
This publication has 11 references indexed in Scilit:
- Application of an RI-beam for cancer therapy: In-vivo verification of the ion-beam range by means of positron imagingNuclear Physics A, 2002
- Design of synchrotron light source and its beamline dedicated to dual-energy x-ray computed tomographyJournal of Biomedical Optics, 2001
- On‐line monitoring of radiotherapy beams: Experimental results with proton beamsMedical Physics, 1999
- Accelerated image reconstruction using ordered subsets of projection dataIEEE Transactions on Medical Imaging, 1994
- Instrumentation for treatment of cancer using proton and light-ion beamsReview of Scientific Instruments, 1993
- Total reaction and partial cross section calculations in proton-nucleus (≤26) and nucleus-nucleus reactions ( and ≤26)Physical Review C, 1993
- Measurements of Interaction Cross Sections and Nuclear Radii in the Light-Shell RegionPhysical Review Letters, 1985
- Particle radiography and autoactivationInternational Journal of Radiation Oncology*Biology*Physics, 1977
- Partial Cross-Sections in High-Energy Nuclear Reactions, and Astrophysical Applications. I. Targets WITh Z <= 28. II. Targets Heavier than NickelThe Astrophysical Journal Supplement Series, 1973
- Energy Straggling of Heavy Charged Particles in Thick AbsorbersPhysical Review B, 1969