A potential method forin vivorange verification in proton therapy treatment
- 19 February 2008
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 53 (5), 1413-1424
- https://doi.org/10.1088/0031-9155/53/5/016
Abstract
Proton therapy potentially offers excellent dose conformality and reduction in integral dose. The superior dose distribution is, however, much more sensitive to the radiological depth along the beam path than for photon fields. Variations in this depth due to inaccurate planning calculation, setup uncertainty, respiration-induced organ motion, etc, could result in either an 'undershooting', missing the distal portion of the target volume entirely, or an 'overshooting', delivering the full prescription dose to the normal tissue beyond the target volume. In vivo dose verification plays an important role in the quality assurance of the treatments. The point dose measurements widely used for photon treatments are, however, insufficient for protons due to the particular characteristics of the proton depth-dose distribution. In this work, we explore a method for in vivo range verifications in proton treatments using range-modulated passive scattering fields. The method utilizes the time dependence of the dose distribution delivered by these fields. By measuring the time dependence of the dose rate at any point in the target volume, the residual range of the beam at this point can be obtained with millimeter accuracy.Keywords
This publication has 17 references indexed in Scilit:
- Sensitivities in the production of spread-out Bragg peak dose distributions by passive scattering with beam current modulationMedical Physics, 2007
- 2514: Biological Lung Phantom for Image-Guided Proton Therapy ValidationInternational Journal of Radiation Oncology*Biology*Physics, 2006
- Optimization of current modulation function for proton spread‐out Bragg peak fieldsMedical Physics, 2006
- Target volume dose considerations in proton beam treatment planning for lung tumorsMedical Physics, 2005
- Intra‐ and interfractional patient motion for a variety of immobilization devicesMedical Physics, 2005
- An analysis of an implantable dosimeter system for external beam therapyInternational Journal of Radiation Oncology*Biology*Physics, 2005
- Charged hadron tumour therapy monitoring by means of PETNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2004
- Organ motion and its managementInternational Journal of Radiation Oncology*Biology*Physics, 2001
- In vivo dosimetry during external photon beam radiotherapyInternational Journal of Radiation Oncology*Biology*Physics, 1999
- Range modulators for protons and heavy ionsNuclear Instruments and Methods, 1975