Abstract
The effect of respiration on heartbeats in a mechanically measured cardiac signal was noticed already in the first respiratory ballistocardiography studies in the 1920s. The effect was described as a modulation of the heartbeat amplitude, and that view has persisted. Although a reasonable approximation, amplitude modulation is not an accurate description of the respiratory effect. In this paper, the respiratory variation is described with a linear latent variable model, where the direction of variation can be distinct from the direction of amplitude. The model was evaluated with seven ballistocardiograms from three healthy test subjects. Based on a Bayesian information criterion analysis, it was found to describe the variation accurately in all the cases. As the modelling of the heartbeat shape is improved, existing heartbeat detection methods can be made more accurate by applying the proposed model.Keywords
This publication has 17 references indexed in Scilit:
- Robust ballistocardiogram acquisition for home monitoringPhysiological Measurement, 2009
- BSeg++: A modified Blind Segmentation Method for Ballistocardiogram Cycle ExtractionPublished by Institute of Electrical and Electronics Engineers (IEEE) ,2007
- Characterization of a novel heart and respiratory rate sensorPublished by Institute of Electrical and Electronics Engineers (IEEE) ,2007
- A new method for measuring the ballistocardiogram using EMFi sensors in a normal chair2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), 2007
- Contact-free measurement of heart rate, respiration rate, and body movements during sleepBehavior Research Methods, 2006
- Air mattress sensor system with balancing tube for unconstrained measurement of respiration and heart beat movementsPhysiological Measurement, 2005
- Bayes FactorsJournal of the American Statistical Association, 1995
- Monitoring of the ballistocardiogram with the static charge sensitive bedIEEE Transactions on Biomedical Engineering, 1991
- Pulse Transit Time and Blood Pressure: An Intensive AnalysisPsychophysiology, 1983
- Recoil curves as shown by the hot-wire microphoneProceedings of the Royal Society of London. Series B, Containing Papers of a Biological Character, 1922