The IPEMB code of practice for the determination of absorbed dose for x-rays below 300 kV generating potential (0.035 mm Al - 4 mm Cu HVL; 10 - 300 kV generating potential)
- 1 December 1996
- journal article
- guideline
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 41 (12), 2605-2625
- https://doi.org/10.1088/0031-9155/41/12/002
Abstract
This new code of practice for the determination of absorbed dose for x-rays below 300 kV has recently been approved by the IPEMB and introduces the following changes to the previous codes: (i) The determination of absorbed dose is based on the air kerma determination (exposure measurement) method. (ii) An air kerma calibration factor for the ionization chamber is used. (iii) The use of the F (rad/röentgen) conversion factor is abandoned and replaced by the ratio of the mass-energy absorption coefficients of water and air for converting absorbed dose to air to absorbed dose to water. New values for ratios of these coefficients are recommended. Perturbation and other correction factors are incorporated in the equations. (iv) New backscatter factors are recommended. (v) Three separate energy ranges are defined, with specific procedures for each range. These ranges are: (a) 0.5 to 4 mm Cu HVL; for this range calibration at 2 cm depth in water with a thimble ion chamber is recommended. (b) 1.0 to 8.0 mm AI HVL; for this range calibration in air with a cylindrical ion chamber and the use of tabulated values of the backscatter factor are recommended. (c) 0.035 to 1.0 mm AI HVL; for this range calibration on the surface of a phantom with a parallel-plate ionization chamber is recommended.Keywords
This publication has 16 references indexed in Scilit:
- Ion recombination corrections for plane-parallel and thimble chambers in electron and photon radiationPhysics in Medicine & Biology, 1993
- Report on the IPSM working party on low- and medium-energy x-ray dosimetryPhysics in Medicine & Biology, 1991
- Complications in low energy X-ray dosimetry caused by electron contaminationPhysics in Medicine & Biology, 1991
- Code of Practice for high-energy photon therapy dosimetry based on the NPL absorbed dose calibration servicePhysics in Medicine & Biology, 1990
- Dependence of the photon backscatter factor for water on source-to-phantom distance and irradiation field sizePhysics in Medicine & Biology, 1990
- Saturation correction for the NE 2560/1 dosemeter in photon dosimetryPhysics in Medicine & Biology, 1990
- Experimentally determined backscatter factors for X-rays generated at voltages between 16 and 140 kVPhysics in Medicine & Biology, 1989
- Revised Code of Practice for the dosimetry of 2 to 35 MV x-ray, and of caesium-137 and cobalt-60 gamma-ray beamsPhysics in Medicine & Biology, 1983
- Central-axis depth-dose data for diagnostic radiologyPhysics in Medicine & Biology, 1981
- The Derivation of Approximate X-ray Spectral Distributions and an Analysis of X-ray “Quality” SpecificationsThe British Journal of Radiology, 1963