Sterility and Microbiological Assessment of Reused Single-Use Cardiac Electrophysiology Catheters
- 1 December 2006
- journal article
- Published by Cambridge University Press (CUP) in Infection Control & Hospital Epidemiology
- Vol. 27 (12), 1385-1392
- https://doi.org/10.1086/508829
Abstract
To assess the performance and limitations of a reprocessing protocol for nonlumen electrophysiology catheters by testing the sterility of reprocessed devices and defining the maximum number of reprocessing cycles sustainable by the device in hygienically safe conditions. Simulated use, reprocessing, and testing of the catheters. Microbiology and virology department of a public health diagnostic laboratory. Seventy-three catheters were collected after clinical use on patients. The first group of devices was tested for sterility after 1 cycle of reprocessing. By the repetition of simulated use (blood inoculated with bacteria) and reprocessing (decontamination, cleaning, and hydrogen peroxide gas plasma sterilization), we obtained 39 sample devices reprocessed 2 times, 26 reprocessed 3 times, 28 reprocessed 4 times, 36 reprocessed 5 times, and 22 reprocessed 6 times. Devices were cultured for 28 days in trypticase soy broth. We tested 208 catheters with 6 cycles of reprocessing and 4 inoculated bacteria species. No devices tested positive for the inoculated strains until the fourth cycle of reprocessing. One of 35 catheters showed the growth of the inoculated strain Bacillus subtilis after 5 cycles of reprocessing, and 1 of 22 catheters showed growth of this organism 6 cycles. After the second reprocessing, 7 of 36 devices showed growth of gram-negative bacteria other than the strain inoculated. Reprocessing according to the reprocessing protocol was insufficient to guarantee device sterility after 5 reuses. Cleaning with enzymatic solution revealed good cleaning properties with efficient bioburden reduction. Storage intervals of longer than 24 hours during reprocessing should be avoided to limit contamination or bacterial overgrowth. Technical considerations suggest the introduction of reprocessing procedures only in hospitals with considerable workloads.Keywords
This publication has 24 references indexed in Scilit:
- A Decontamination and Sterilization Protocol Employed During Reuse of Cardiac Electrophysiology Catheters Inactivates Human Immunodeficiency VirusInfection Control & Hospital Epidemiology, 2003
- Reprocessing of thermosensitive materials — efficacy against bacterial spores and virusesJournal of Hospital Infection, 2001
- Cleaning of Blood-Contaminated Reprocessed Angiographic Catheters and Spinal NeedlesInfection Control & Hospital Epidemiology, 2000
- The Presterilization Microbial Load on Used Medical Devices and the Effectiveness of Hydrogen Peroxide Gas Plasma AgainstBacillus SubtilisSporesInfection Control & Hospital Epidemiology, 1999
- Inactivation of duck hepatitis B virus by a hydrogen peroxide gas plasma sterilization system: laboratory and ‘in use’ testingJournal of Hospital Infection, 1999
- Inactivation of human immunodeficiency virus type 1, hepatitis A virus, respiratory syncytial virus, accinia virus, herpes simplex virus type 1, and poliovirus type 2 by hydrogen peroxide gas plasma sterilizationAmerican Journal of Infection Control, 1998
- Gas–plasma sterilization: relative efficacy of the hydrogen peroxide phase compared with that of the plasma phaseInternational Journal of Pharmaceutics, 1998
- Safety of reusing cardiac electrophysiology cathetersThe American Journal of Cardiology, 1994
- Repeated use of ablation catheters: A prospective studyJournal of the American College of Cardiology, 1993
- Success of re-use of cardiac electrode cathetersThe American Journal of Cardiology, 1987