Influence of Radiation Damage on Hyperfine-Interaction Measurements after Implantation in Metals

Abstract
We report electron microscopy experiments showing that the spatial distribution of damage produced in metals by implanted ions is generally quite different from that of the ions themselves. We discuss how this affects hyperfine-interaction measurements.