Combined knee loading states that generate high anterior cruciate ligament forces
- 1 November 1995
- journal article
- research article
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 13 (6), 930-935
- https://doi.org/10.1002/jor.1100130618
Abstract
Injuries to the anterior cruciate ligament frequently occur under combined mechanisms of loading. This in vitro study was designed to measure levels of ligament force under dual combinations of individual loading states and to determine which combinations generated high force. Resultant force was recorded as the knee was extended passively from 90° of flexion to 5° of hyperextension under constant tibial loadings. The individual loading states were 100 N of anterior tibial force, 10 Nm of varus and valgus moment, and 10 Nm of internal and external tibial torque. Straight anterior tibial force was the most direct loading, mechanism; the mean ligament force was approximately equal to applied anterior tibial force near 30° of flexion and to 150% of applied tibial force at full extension. The addition of internal tibial torque to a knee loaded by anterior tibial force produced dramatic increases of force at full extension and hyperextension. This loading combination produced the highest ligament forces recorded in the study and is the most dangerous in terms of potential injury to the ligament. In direct contrast, the addition of external tibial torque to a knee loaded by anterior tibial force decreased the force dramatically for flexed positions of the knee; at close to 90° of flexion, the anterior cruciate ligament became completely unloaded. The addition of varus moment to a knee loaded by anterior tibial force increased the force in extension and hyperextension, whereas the addition of valgus moment increased the force at flexed positions. These states of combined loading also could present an increased risk for injury. Internal tibial torque is an important loading mechanism of the anterior cruciate ligament for an extended knee. The overall risk of injury to the ligament from varus or valgus moment applied in combination with internal tibial torque is similar to the risk from internal tibial torque alone. External tibial torque was a relatively unimportant mechanism for generating anterior cruciate ligament force.Keywords
This publication has 8 references indexed in Scilit:
- The effect of section of the medial collateral ligament on force generated in the anterior cruciate ligament.Journal of Bone and Joint Surgery, 1991
- Method for setting total graft force and load sharing in augmented ACL graftsJournal of Orthopaedic Research, 1990
- Direct measurement of resultant forces in the anterior cruciate ligament. An in vitro study performed with a new experimental technique.Journal of Bone and Joint Surgery, 1990
- Knee Joint Motion and Ligament Forces Before and After ACL ReconstructionJournal of Biomechanical Engineering, 1989
- In‐vitro ligament tension pattern in the flexed knee in passive loadingJournal of Orthopaedic Research, 1987
- A Note on the Application and Evaluation of the Buckle Transducer for Knee Ligament Force MeasurementJournal of Biomechanical Engineering, 1982