Agreement Between Gonioscopy and Ultrasound Biomicroscopy in Detecting Iridotrabecular Apposition
- 1 October 2007
- journal article
- research article
- Published by American Medical Association (AMA) in Archives of Ophthalmology (1950)
- Vol. 125 (10), 1331-1335
- https://doi.org/10.1001/archopht.125.10.1331
Abstract
Objective To assess the agreement between findings obtained at dark-room gonioscopy and ultrasound biomicroscopy (UBM) in the diagnosis of iridotrabecular apposition in light and dark conditions. Methods We enrolled patients with appositional angle closure at dark-room gonioscopy performed using a 1-mm slitlamp beam that did not cross the pupil. Ultrasound biomicroscopic images were acquired in normal room light and subsequently with all room lights off. Images were evaluated for the presence or absence of iris-cornea contact. The angle opening distance at 500 μm was calculated. Results Iridotrabecular apposition in at least 1 angle quadrant was demonstrated in all 18 eyes at dark-room gonioscopy, 17 eyes (94%) at dark-room UBM, and only 10 eyes (56%) at UBM in room light. Of 18 superior angles that were appositionally closed at dark-room gonioscopy, apposition was demonstrated on UBM images in 16 (89%) in a dark room but only 6 (33%) in room light. Angle opening distance was less during dark-room gonioscopy in all but the nasal quadrant. Conclusion We found high agreement between gonioscopy and UBM when both are performed in a completely dark room. Our findings support the recommendation that, in routine clinical practice, gonioscopy be performed in a dark room to avoid misdiagnosis of treatable iridotrabecular apposition.Keywords
This publication has 10 references indexed in Scilit:
- Defining "occludable" angles in population surveys: drainage angle width, peripheral anterior synechiae, and glaucomatous optic neuropathy in east Asian peopleBritish Journal of Ophthalmology, 2004
- A prospective ultrasound biomicroscopy evaluation of changes in anterior segment morphology after laser iridotomy in asian eyesOphthalmology, 2003
- Quantitative assessment of the anterior segment using ultrasound biomicroscopyCurrent Opinion in Opthalmology, 2000
- Ultrasound biomicroscopy dark room provocative testing: a quantitative method for estimating anterior chamber angle width.Japanese Journal of Ophthalmology, 1999
- Plateau iris syndrome: changes in angle opening associated with dark, light, and pilocarpine administrationAmerican Journal of Ophthalmology, 1999
- Ultrasound biomicroscopic quantitative analysis of light-dark changes associated with pupillary blockAmerican Journal of Ophthalmology, 1999
- Ultrasound Biomicroscopy in Plateau Iris SyndromeAmerican Journal of Ophthalmology, 1992
- Ultrasound Biomicroscopy of Anterior Segment Structures in Normal and Glaucomatous EyesAmerican Journal of Ophthalmology, 1992
- Plateau Iris Is Caused by Abnormally Positioned Ciliary ProcessesJournal of Glaucoma, 1992
- Clinical Use of Ultrasound BiomicroscopyOphthalmology, 1991