Low-Dose Hypersensitivity in Chinese Hamster V79 Cells Targeted with Counted Protons Using a Charged-Particle Microbeam
- 1 November 2001
- journal article
- Published by Radiation Research Society in Radiation Research
- Vol. 156 (5), 526-534
- https://doi.org/10.1667/0033-7587(2001)156[0526:ldhich]2.0.co;2
Abstract
Schettino, G., Folkard, M., Prise, K. M., Vojnovic, B., Bowey, A. G. and Michael, B. D. Low-Dose Hypersensitivity in Chinese Hamster V79 Cells Targeted with Counted Protons Using a Charged-Particle Microbeam. Radiat. Res. 156, 526–534 (2001).The Gray Laboratory charged-particle microbeam has been used to assess the clonogenic ability of Chinese hamster V79 cells after irradiation of their nuclei with a precisely defined number of protons with energies of 1.0 and 3.2 MeV. The microbeam uses a 1-μm silica capillary collimator to deliver protons to subcellular targets with high accuracy. The detection system is based on a miniature photomultiplier tube positioned above the cell dish, which detects the photons generated by the passage of the charged particles through an 18-μm-thick scintillator placed below the cells. With this system, a detection efficiency of greater than 99% is achieved. The cells are plated on specially designed dishes (3-μm-thick Mylar base), and the nuclei are identified by fluorescence microscopy. After an incubation period of 3 days, the cells are revisited individually to assess the formation of colonies from the surviving cells. For each energy investigated, the survival curve obtained for the microbeam shows a significant deviation below 1 Gy from a response extrapolated using the LQ model for the survival data above 1 Gy. The data are well fitted by a model that supports the hypothesis that radioresistance is induced by low-dose hypersensitivity. These studies demonstrate the potential of the microbeam for performing studies of the effects of single charged particles on cells in vitro. The hypersensitive responses observed are comparable with those reported by others using different radiations and techniques.Keywords
This publication has 20 references indexed in Scilit:
- Measurements of the targeting accuracy of the Gray Laboratory charged-particle microbeamNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 2001
- A new alpha-particle irradiator with absolute dosimetric determination.Radiation Research, 2000
- A charged-particle microbeam: II. A single-particle micro-collimation and detection system.International Journal of Radiation Biology, 1997
- Inactivation of individual mammalian cells by single alpha-particlesInternational Journal of Radiation Biology, 1997
- Low dose hyper-radiosensitivity and increased radioresistance in mammalian cellsInternational Journal of Radiation Biology, 1997
- A charged-particle microbeam: I. Development of an experimental system for targeting cells individually with counted particlesInternational Journal of Radiation Biology, 1997
- Meeting Report: Microbeam Probes of Cellular Radiation Response, 4th L. H. Gray Workshop, 8–10 July 1993International Journal of Radiation Biology, 1994
- Hypersensitive Response of Normal Human Lung Epithelial Cells at Low Radiation DosesInternational Journal of Radiation Biology, 1994
- Radiobiological experiments in space: A reviewInternational Journal of Radiation Applications and Instrumentation. Part D. Nuclear Tracks and Radiation Measurements, 1992
- Studying Low Dose Effects Using Single Particle Microbeam IrradiationRadiation Protection Dosimetry, 1990