A New Model for Evaluation of Biocompatibility: Combined Determination of Neoepitopes in Blood and on Artificial Surfaces Demonstrates Reduced Complement Activation by Immobilization of Heparin
- 1 September 1995
- journal article
- Published by Wiley in Artificial Organs
- Vol. 19 (9), 909-917
- https://doi.org/10.1111/j.1525-1594.1995.tb02450.x
Abstract
An in vitro technique was developed for assessment of the biocompatibility of materials for use in clinical applications. Artificial materials were exposed to blood, and the resulting complement activation was quantified both in the plasma and on the material surface by enzyme immunoassays based on monoclonal antibodies specific for neoepitopes exposed in complement activation products. Several materials were evaluated, and the effect of surface modifications, including end–point immobilized heparin, was studied. The results revealed widely varying complement activation properties of the different materials and confirmed that heparin markedly improves biocompatibility. The present method is superior to analysis limited to either the fluid phase or solid phase since certain materials adsorb activation products (exemplified by Tecoflex) whereas others do not although activation was evident from fluid–phase assay (silicone). Furthermore, direct determination of activation–specific neoepitopes on the surface represents an improvement compared with previously described methods for detection of adsorbed components.Keywords
This publication has 53 references indexed in Scilit:
- Strategy for in vitro evaluation of the interactions between biomaterials and complement systemJournal of Applied Biomaterials, 1993
- Complement activation in septic baboons detected by neoepitope-specific assays for C3b/iC3b/C3c, C5a and the terminal C5b-9 complement complex (TCC)Clinical and Experimental Immunology, 1993
- Complement activation and adsorption of protein fragments by functionalized polymer surfaces in human serumBiomaterials, 1992
- Complement activation with bubble and membrane oxygentors in aortocorpnary bypass graftingThe Annals of Thoracic Surgery, 1990
- Activation of complement by hemodialysis membranes: Polyacrylonitrile binds more C3a than cuprophanKidney International, 1990
- Identification of plasma proteins adsorbed to hemodialyzers during clinical useJournal of Biomedical Materials Research, 1989
- Deposition of Terminal C5b–9 Complement Complexes on Erythrocytes and Leukocytes during Cardiopulmonary BypassNew England Journal of Medicine, 1988
- Separation of self from non-self in the complement systemImmunology Today, 1987
- Complement Activation and Hypersensitivity Reactions to Dialysis MembranesNew England Journal of Medicine, 1984
- Complement Activation during Cardiopulmonary BypassNew England Journal of Medicine, 1981