DETECTION, LOCALIZATION, AND QUANTITATION OF DEGREE OF COMMON BILE-DUCT OBSTRUCTION BY SCINTIGRAPHY
- 1 January 1985
- journal article
- research article
- Vol. 26 (7), 726-735
Abstract
The detection, localization and quantitation of the degree of obstruction was successfully accomplished by [99mTc]IDA [iminodiacetic acid] scintigraphy in 13 of 14 patients with cholangiographically documented common bile duct (CBD) obstruction. Ductal dilatation was present on ultrasound examination in only 7 patients. The accuracy of biliary scintigraphy was enhanced by several innovations including: selection of a radiopharmaceutical with rapid hepatic uptake and excretion; shorter imaging interval over longer period of time; substitution of image parameter for appearance time; and quantitative measurement of bile emptying parameters following cholecystokinin infusion. Scintigraphically, the partial obstruction was characterized by CBD segmental narrowing or intraluminal filling defects and bile stasis within the area and segmental ducts. The gallbladder mean (.+-. SD) ejection fraction of 20.0 .+-. 17.5%, ejection period of 6.8 .+-. 1.6 min, and ejection rate of 3.1 .+-. 2.6%/min following 3-min infusion of 10 ng/kg of cholecystokinin octapeptide were reduced significantly when compared to control subjects. The level of CBD obstruction correlated well with the results of cholangiography. Quantitative biliary dynamic scintigraphy employing modern techniques can accurately detect and localize CBD obstruction.This publication has 1 reference indexed in Scilit:
- Ultrasonography in the Diagnosis of Obstructive JaundiceAnnals of Internal Medicine, 1978