Contrast Enhancement

Abstract
Contrast enhancement attenuation units were calculated from 13 tissues and organs of 20 rats at 5 different times after bolus 125I-diatrizoate administration. Percent distribution volume of diatrizoate was calculated from these results. Statistical significance of differences in contrast enhancement between each of 72 tissue pairs was determined at each of the 5 times. A similar treatment of percent distribution volume for 60 tissue pairs was determined. The time elapsed after contrast medium injection apparently was of pivotal importance in contrast enhancement diagnosis. Calculation of percent contrast distribution volume was of potential diagnostic importance, since it revealed contrast medium behavior not evident from a visual perusal of scans. The above methods can be readily adapted to computed tomography scanning.

This publication has 1 reference indexed in Scilit: