Combination of a Low-Tube-Voltage Technique With Hybrid Iterative Reconstruction (iDose) Algorithm at Coronary Computed Tomographic Angiography
- 1 July 2011
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
- Vol. 35 (4), 480-485
- https://doi.org/10.1097/rct.0b013e31821fee94
Abstract
We compare the performance of low tube voltage with the hybrid iterative reconstruction (iDose) with standard and low tube voltage with the filtered backprojection (FBP) using phantoms at computed tomographic coronary angiography. In computed tomographic coronary angiography, application of the combined low tube voltage with iDose resulted in significant image quality improvements compared to the low tube voltage with FBP. Image quality was the same or better despite a reduction in the radiation dose by 76% compared with standard tube voltage with FBP.Keywords
This publication has 21 references indexed in Scilit:
- Use of 100 kV versus 120 kV in cardiac dual source computed tomography: effect on radiation dose and image qualityThe International Journal of Cardiovascular Imaging, 2010
- Low-Tube-Voltage, High-Tube-Current Multidetector Abdominal CT: Improved Image Quality and Decreased Radiation Dose with Adaptive Statistical Iterative Reconstruction Algorithm—Initial Clinical ExperienceRadiology, 2010
- Diagnostic Performance of Coronary Angiography by 64-Row CTNew England Journal of Medicine, 2008
- Evaluation of Coronary Stent Patency and In-Stent Restenosis with Dual-Source CT Coronary Angiography Without Heart Rate ControlAmerican Journal of Roentgenology, 2008
- Effect of Decrease in Heart Rate Variability on the Diagnostic Accuracy of 64-MDCT Coronary AngiographyAmerican Journal of Roentgenology, 2008
- Low Tube Voltage Improves Computed Tomography Imaging of Delayed Myocardial Contrast Enhancement in an Experimental Acute Myocardial Infarction ModelInvestigative Radiology, 2007
- Abdominal CT with Low Tube Voltage: Preliminary Observations about Radiation Dose, Contrast Enhancement, Image Quality, and NoiseRadiology, 2005
- Radiation Dose Reduction without Degradation of Low-Contrast Detectability at Abdominal Multisection CT with a Low–Tube Voltage Technique: Phantom StudyRadiology, 2005
- High-Resolution Spiral Computed Tomography Coronary Angiography in Patients Referred for Diagnostic Conventional Coronary AngiographyCirculation, 2005
- Accuracy of MSCT coronary angiography with 64-slice technology: first experienceEuropean Heart Journal, 2005