Clinical and Optical Intraocular Performance of Rotationally Asymmetric Multifocal IOL Plate-Haptic Design Versus C-Loop Haptic Design
- 1 April 2013
- journal article
- research article
- Published by SLACK, Inc. in Journal of Refractive Surgery
- Vol. 29 (4), 252-259
- https://doi.org/10.3928/1081597x-20130318-04
Abstract
PURPOSE: To compare the visual and intraocular optical quality outcomes with different designs of the refractive rotationally asymmetric multifocal intraocular lens (MFIOL) (Lentis Mplus; Oculentis GmbH, Berlin, Germany) with or without capsular tension ring (CTR) implantation. METHODS: One hundred thirty-five consecutive eyes of 78 patients with cataract (ages 36 to 82 years) were divided into three groups: 43 eyes implanted with the C-Loop haptic design without CTR (C-Loop haptic only group); 47 eyes implanted with the C-Loop haptic design with CTR (C-Loop haptic with CTR group); and 45 eyes implanted with the plate-haptic design (plate-haptic group). Visual acuity, contrast sensitivity, defocus curve, and ocular and intraocular optical quality were evaluated at 3 months postoperatively. RESULTS: Significant differences in the postoperative sphere were found ( P = .01), with a more myopic postoperative refraction for the C-Loop haptic only group. No significant differences were detected in photopic and scotopic contrast sensitivity among groups ( P ⩾ .05). Significantly better visual acuities were present in the C-Loop haptic with CTR group for the defocus levels of −2.0, −1.5, −1.0, and −0.50 D ( P ⩽.03). Statistically significant differences among groups were found in total intraocular root mean square (RMS), high-order intraocular RMS, and intraocular coma-like RMS aberrations ( P ⩽.04), with lower values from the plate-haptic group. CONCLUSIONS: The plate-haptic design and the C-Loop haptic design with CTR implantation both allow good visual rehabilitation. However, better refractive predictability and intraocular optical quality was obtained with the plate-haptic design without CTR implantation. The plate-haptic design seems to be a better design to support rotational asymmetric MFIOL optics. [ J Refract Surg. 2013;29(4):252–259.]Keywords
This publication has 23 references indexed in Scilit:
- Rotationally Asymmetric Multifocal IOL Implantation With and Without Capsular Tension Ring: Refractive and Visual Outcomes and Intraocular Optical PerformanceJournal of Refractive Surgery, 2012
- Comparison of a New Refractive Multifocal Intraocular Lens with an Inferior Segmental Near Add and a Diffractive Multifocal Intraocular LensOphthalmology, 2012
- Comparison of the Visual and Intraocular Optical Performance of a Refractive Multifocal IOL With Rotational Asymmetry and an Apodized Diffractive Multifocal IOLJournal of Refractive Surgery, 2012
- Comparative analysis of the clinical outcomes with 2 multifocal intraocular lens models with rotational asymmetryJournal of Cataract & Refractive Surgery, 2011
- Rotational stability and posterior capsule opacification of a plate-haptic and an open-loop-haptic intraocular lensJournal of Cataract & Refractive Surgery, 2011
- Visual outcomes and optical performance of a monofocal intraocular lens and a new-generation multifocal intraocular lensJournal of Cataract & Refractive Surgery, 2011
- Expanding depth of focus by modifying higher-order aberrations induced by an adaptive optics visual simulatorJournal of Cataract & Refractive Surgery, 2009
- Microincision multifocal intraocular lens with and without a capsular tension ringJournal of Cataract & Refractive Surgery, 2008
- Evidence for Delayed Presbyopia after Photorefractive Keratectomy for MyopiaOphthalmology, 2006
- Optical performance of 3 intraocular lens designs in the presence of decentrationJournal of Cataract & Refractive Surgery, 2005