Repositioning Accuracy with the Laitinen Frame for Fractionated Stereotactic Radiation Therapy in Adult and Pediatric Brain Tumors: Preliminary Report
- 1 January 2001
- journal article
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 218 (1), 157-161
- https://doi.org/10.1148/radiology.218.1.r01ja23157
Abstract
To determine the repositioning accuracy, patient tolerance, and clinical efficacy of stereotactic radiation therapy for brain tumors in children and adults performed with the Laitinen stereotactic localizer and head holder. In this retrospective analysis, stereotactic frame tolerance was assessed by recording patient discomfort or pain in the ear and nose during each treatment in 34 patients, including 21 children and 13 adults with 37 lesions treated with fractionated stereotactic radiation therapy. Radiation doses ranged from 10-60 Gy at 1.0-4.0 Gy per fraction. Repositioning accuracy was assessed by comparing portal radiographs with setup fields on computed tomographic (CT) scout images. Clinical efficacy was assessed by analyzing posttreatment CT and magnetic resonance images. The stereotactic localizer was well tolerated. The mean isocenter shifts observed after studying 305 portal radiographs were x-coordinate shift of 1.0 mm +/- 0.7 (SD), y-coordinate shift of 0.8 mm +/- 0.8, and z-coordinate shift of 1.7 mm +/- 1.0. At a median follow-up of 16 months, local control was achieved in 18 of 22 primary and in one of eight of recurrent tumors. The Laitinen stereotactic localizer is well tolerated with accurate reproducibility during stereotactic radiation therapy. Preliminary local control rates are consistent with those in other reports.Keywords
This publication has 23 references indexed in Scilit:
- Clinical commissioning of Laitinen Stereoadapter for fractionated stereotactic radiotherapyMedical Dosimetry, 1998
- The Use of the Laitinen Stereoadapter for Three-Dimensional Conformal Stereotactic RadiotherapyJournal of Radiosurgery, 1998
- Dose—response tolerance of the visual pathways and cranial nerves of the cavernous sinus to stereotactic radiosurgeryJournal of Neurosurgery, 1998
- Principles of Dose Prescription and Risk Minimization for RadiosurgeryPublished by S. Karger AG ,1998
- IntroductionPublished by S. Karger AG ,1998
- Adaptation and verification of the relocatable gill-thomas-cosman frame in stereotactic radiotherapyInternational Journal of Radiation Oncology*Biology*Physics, 1994
- Quality assurance in stereotactic radiosurgery using a standard linear acceleratorInternational Journal of Radiation Oncology*Biology*Physics, 1991
- Variables associated with the development of complications from radiosurgery of intracranial tumorsInternational Journal of Radiation Oncology*Biology*Physics, 1991
- A non-invasive method for fractionated stereotactic irradiation of brain tumors with linear acceleratorRadiotherapy and Oncology, 1990
- Stereotactic radiosurgery.Journal of Neurology, Neurosurgery & Psychiatry, 1983